YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Effects of Flexible Plate Attached To the Rear of the Cylinder on Flow Structure

dc.authorscopusid 56728619900
dc.authorscopusid 35323147200
dc.authorwosid Teksin, Suleyman/Afk-3449-2022
dc.authorwosid Yayla, Sedat/Gzh-0085-2022
dc.contributor.author Teksin, Suleyman
dc.contributor.author Yayla, Sedat
dc.date.accessioned 2025-05-10T17:28:14Z
dc.date.available 2025-05-10T17:28:14Z
dc.date.issued 2017
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Teksin, Suleyman; Yayla, Sedat] Yuzuncu Yil Univ, Dept Mech Engn, Van, Turkey en_US
dc.description.abstract In this experimental study, the flow structure in the wake flow region was investigated with the Particle image velocimetry technique (PIV) by attaching elastic plates at different lengths behind the cylinder. The flow structure occurred at the wake flow region altered depending on the length of the flexible matter. In this experiment, the strips with the lengths of 75, 90, 120, 135 and 180 mm were used to control instabilities. Diameter of the cylinder (D) is 60 mm and the water height (h(w)) is 600 mm. Reynolds number was kept constant as 5000 based on cylinder diameter. The images were captured at mid-height of the cylinder (h(m)) which is 250 mm. As a result of experimental studies, attached flexible strip suppressed vortex shedding occurred in the behind of the cylinder and it is observed that effect of the length flexible of the strip is pretty much. Maximum level of flow characteristics such as Reynolds stress, fluctuation velocities and turbulent kinetic energy were decreased with flexible splitter plate and shifted through the downstream region. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1007/s12206-017-0218-y
dc.identifier.endpage 1201 en_US
dc.identifier.issn 1738-494X
dc.identifier.issn 1976-3824
dc.identifier.issue 3 en_US
dc.identifier.scopus 2-s2.0-85016067551
dc.identifier.scopusquality Q3
dc.identifier.startpage 1195 en_US
dc.identifier.uri https://doi.org/10.1007/s12206-017-0218-y
dc.identifier.uri https://hdl.handle.net/20.500.14720/11990
dc.identifier.volume 31 en_US
dc.identifier.wos WOS:000397992600020
dc.identifier.wosquality Q4
dc.language.iso en en_US
dc.publisher Korean Soc Mechanical Engineers en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Cylinder en_US
dc.subject Passive Control en_US
dc.subject Flexible Strip en_US
dc.subject Flow Structure en_US
dc.subject Piv en_US
dc.title Effects of Flexible Plate Attached To the Rear of the Cylinder on Flow Structure en_US
dc.type Article en_US

Files