Browsing by Author "Eskitascioglu, M."
Now showing 1 - 5 of 5
- Results Per Page
- Sort Options
Article Changes in the Surface of Bone and Acid-Etched and Sandblasted Implants Following Implantation and Removal(Dental Investigations Society, 2016) Eroglu, C.N.; Ertugrul, A.S.; Eskitascioglu, M.; Eskitascioglu, G.Objective: The aim of this study was to determine whether there are any changes in the surface of bone or implant structures following the removal of a screwed dental implant. Materials and Methods: For this, six individual samples of acid-etched and sandblasted implants from three different manufacturers' implant systems were used. They were screwed in a D1 bovine bone, and they were removed after primary stabilization. The bone and implant surfaces are evaluated with scanning electron microscope. Results: Through examination of the surfaces of the bone prior to implantation and of the used and unused implant surfaces, it was found that inhomogeneity in the implant surface can cause microcracking in the bone. Conclusions: This is attributed to the stress induced during the implantation of self-tapping implants and suggests that a tap drill may be required in some instances to protect the implant surface. © 2016 European Journal of Dentistry.Article The Effect of Different Materials and Techniques on Stress Distribution in Cad/Cam Endocrowns(Springer, 2020) Eskitascioglu, M.; Kucuk, O.; Eskitascioglu, G.; Eraslan, O.; Belli, S.Computer-aided design/manufacturing (CAD/CAM) endocrowns are commonly applied to strengthen endodontically treated teeth with too much tissue loss. Monolithic or multilayer structures may be used for this purpose. Restorations made with multilayering technique may mimic natural teeth better. The purpose of this finite elemental analysis (FEA) research was to appraise the impact of different materials and application methods on the stress effect in CAD/CAM applied endocrowns. A 3-dimensional mathematical model simulating an endodontically treated mandibular first molar was modeled. The sample was then modified to imitate the ceramic endocrown applied molar tooth. Three FEA models were then created from this main model to simulate the following endocrown structures: 1: lithium disilicate reinforced glass ceramic, 2: monolithic zirconia, 3: multi-layered glass ceramic and glass-fiber endocrown (the core structure was composed of glass-fiber while the crown is prepared by glass ceramic). The SolidWorks/CosmosWorks programs were used as structural analysis programs. The materials used in the study were accepted as homogeneous and isotropic. A 300 N load was applied to the occlusal surfaces of the restored teeth. The results of the study are presented according to the von Mises criteria. The von Mises stresses recorded at the cavity base were 0.417-0.7, 0.6-0.85, and 0.083-0.25 MPa, respectively. The multilayering technique reduced stresses as compared to the other two different designs and materials and showed similar stress distributions with the natural tooth model. Models simulating teeth with a zirconia endocrown showed the highest stresses. The multilayering technique using fiber-reinforced glass ceramic as a core and glass ceramic as a crown reduced the stresses and showed stress distributions similar to natural teeth. This technique can be used to create biomimetic restorations with a core material, which mimics dentin (glass-fiber reinforced ceramic) and crown material, which mimics enamel (glass ceramic).Article Effects of Naocl, Edta and Mtad When Applied To Dentine on Stress Distribution in Post-Restored Roots With Flared Canals(Wiley, 2014) Belli, S.; Eraslan, O.; Eraslan, O.; Eskitascioglu, M.; Eskitascioglu, G.AimTo evaluate the effect of NaOCl, EDTA and MTAD on the stress distribution and levels in roots with flared canals and three different aesthetic post systems using finite element stress analysis (FEA). MethodologyThree-dimensional (3D) FEA models simulating a maxillary incisor with excessive structural loss and flared root canals were created. The dentine of the first models of each post group was assumed as homogenous, whereas the others were deemed as having their elastic modulus affected up to 100m deep as a result of irrigation protocol (5.25 NaOCl, 17% EDTA and MTAD for 2h). A sound incisor tooth model was used as the control. Restorations were created according to the post system used (pre-fabricated fibre post (PFP)), polyethylene fibre (Ribbond) post and core build-up (RBP), and one-piece milled zirconia post and core (ZP). Ceramic crowns were added to the models. A 300-N static load was applied at the centre of the palatal surface of the models to calculate the stress distributions. The SolidWorks/Cosmosworks structural analysis programmes were used for FEA analysis. Results were presented by considering von Mises criteria. ResultsThe analysis of the von Mises stresses revealed that RBP created less stress in the remaining root dentine when compared to PFP and ZP. ZP maintained the stresses inside its body and reduced stress on the palatal surface of the root; however, it forwarded more stress towards the apical area. NaOCl-, EDTA- and MTAD-treated dentine increased the stresses within the root structure regardless of the effect of the post system used (11-15.4 MPa for PFP, 9.5-13.02 MPa for RBP and 14.2 MPa for ZP). Amongst the irrigation solutions used, EDTA and MTAD increased the stresses more than NaOCl in all models. All the irrigation solutions showed the same stress levels and distributions in the ZP model. ConclusionNaOCl-, EDTA- and MTAD- treated dentine and a rigid post with high elastic modulus may increase fracture risk in roots with flared canals by increasing the stresses within root dentine. Therefore, solutions that alter the elastic modulus of dentine less (such as NaOCl) or an individually shaped post-core system constructed with a material that has an elastic modulus close to dentine (polyethylene fibre) should be used in weak roots.Erratum Retraction: Stress Distribution in Cad/Cam Endocrowns Produced Via Different Materials and Techniques: a Numerical Simulation (Retraction of Vol 52, Pg 812, 2020)(Springer, 2023) Eskitascioglu, M.; Kucuk, O.; Eskitascioglu, G.; Eraslan, O.; Belli, S.Article Stress Distribution in Cad/Cam Endocrowns Produced Via Different Materials and Techniques: a Numerical Simulation(Springer, 2022) Eskitascioglu, M.; Kucuk, O.; Eskitascioglu, G.; Eraslan, O.; Belli, S.Computer-aided design/manufacturing (CAD/CAM) endocrowns are commonly applied for the strengthening of endodontically treated teeth with excessive tissue loss. Monolithic or multilayer structures may be used for this purpose. Restorations made with multilayering techniques may better mimic natural teeth. This study assessed the impact of different materials and application methods on the stress state of CAD/CAM endocrowns. To this end, a 3D FEM model simulating an endodontically treated mandibular first molar was elaborated. The sample was then modified to imitate the ceramic endocrown-applied molar tooth. Three FEM models were then developed from this main model to simulate the following endocrown structures: (1) lithium disilicate reinforced glass ceramic, (2) monolithic zirconia, and (3) multilayered glass ceramic and glass-fiber endocrown (i.e., a glass-fiber core structure and glass ceramic crown). The SolidWorks/Cosmosworks software packages were used for structural analysis. The materials used in the study were treated as homogeneous and isotropic. A 300 N load was applied to the occlusal surfaces of the restored teeth. The von Mises stresses were calculated at the cavity base, ranging from 0.417-0.700 MPa, 0.600-0.850 MPa, and 0.083-0.250 MPa, respectively. The multilayering technique provided the lowest stresses and stress distributions comparable with the natural tooth model. Models of teeth restored with zirconia endocrowns showed the highest stresses and were the least applicable in dental pracice.