Browsing by Author "Gencoglan, Cafer"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Article Creating a Solar Radiation Measuring System (Srms) Operated by a Programmable Logic Controller (Plc)(Univ Namik Kemal, 2021) Gencoglan, Serpil; Gencoglan, Cafer; Usta, SelcukIn this study, it is aimed to create a PLC controlled SRMS to be used in rural areas. Firstly a SRMS hardware was prepared consisting of power supply, PLC, analogue module and pyranometer units. Then, a SRMS software was written using CODESYS programming language to measure and record data and to control the hardware by PLC. SRMS software firstly collected the solar radiation in cumulatively by measuring every 30 minutes during the one day period, and determined the daily total solar radiation. Then it calculated the daily average solar radiation by dividing the daily total solar radiation by the number of measurements. It recorded the daily total and average solar radiation amounts on the SD card. SRMS was tested in Kahramanmaras Sutcu Imam University (KSU) during the July-November period of the 2019. The daily average solar radiation data recorded at KSU were compared with the data measured in the same period at the Eastern Mediterranean Transition Area Agricultural Research Institute (DAGTEM), located 10 km away. The daily average solar radiation data measured in KSU and DAGTEM varied between 3.63-33.48 MJ m(-2) day(-1) and 3.00-33.00 MJ m(-2) day(-1), respectively. Five-month averages of daily solar radiation data measured at both regions were determined 20.20 MJ m-2 day(-1) and 19.64 MJ m(-2) day(-1), respectively. The difference between the mean of KSU and DAGTEM data groups was not found to be statistically significant (p> 0.05). This result revealed that the daily average solar radiation values measured in both regions can be used interchangeably. As an expression of the deviation between data groups measured in both regions, the MAPE and RMSE were determined as 14.57% and 2.68 MJ m(-2) day(-1). The compatibility level of the data groups was obtained as "good" (MAPE= 10-20%). It was concluded that SRMS could measure the daily average solar radiation with high accuracy and could be used in sensitive measurements.Article Measurement of Water Depth in a Class a Pan Using Ultrasonic Transducer and Programmable Logic Control (Plc)(Univ Namik Kemal, 2023) Gencoglan, Cafer; Gencoglan, Serpil; Usta, SelcukThe aim of this study is to compare water depths measured by manually and PLC from a Class A Pan in field conditions using ultrasonic transducer. The study was conducted in garden of Faculty of Agriculture, University of Kahramanmaras Sutcu Imam in the summer season of 2019. A steel meter was used to measure water depth manually in the evaporation pan. Using the ultrasonic transducer, PLC measured water depth from the evaporation pan between 140 and 223 mm water depth at 8:00 am. An ultrasonic transducer is attached one end of sliding buttress, at which was 50 cm above from its inner-bottom at the center of the evaporation pan. The ultrasonic transducer was set to be able to read water depth and calibrated using sliding buttress. A program was written in CODESYS-ST language to measure the water depth from a Class A Pan using PLC, which was connected the ultrasonic transducer and uploaded to PLC. With the program, digital water depths were converted to millimeter water depths. To be able to read the water depth more accurately, each depth value read by the PLC was determined by averaging 30 measurements made successively at 300 millisecond intervals. In this processes, moving average method was used. Water depth measured by PLC was saved on the SD (secure digital memory) card. In the manual water depth measurements, there were 26 observations. The water depths on the manual measurement dates were matched with the water depths measured by PLC. A regression analysis was performed between the water depths measured by the steel meter and PLC in the pan, and determination coefficient (R2) was result as 0.96. The Mean Absolute Percent Error (MAPE) of these two data sets was calculated as 2.3%. The level of agreement between the two data sets; if the MAPE is below 10%, it is considered "very good". The results of this study revealed that the PLC could measure the water depth close to the measured manually water depth in the evaporation pan with an ultrasonic transducer.