Evaluating the Masking Ability of Cad/Cam Hybrid Ceramics With Different Thicknesses

dc.contributor.author Rasool, Farhad Wahid
dc.contributor.author Değirmenci, Beyza Ünalan
dc.date.accessioned 2025-05-10T17:17:37Z
dc.date.available 2025-05-10T17:17:37Z
dc.date.issued 2021
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp Yabancı Kurumlar,Van Yüzüncü Yil Üni̇versi̇tesi̇ en_US
dc.description.abstract Aim: A discoloration existing under tooth restoration can affect the final restoration color, and various techniques can be used to address this. The aim of this study was to investigate the masking ability of the substructure color of different hybrid CAD/CAM ceramics in various thicknesses. Methodology: A total of 120 samples were produced from 4 different CAD/CAM hybrid ceramic blocks (Cerec blocs, GC Cerasmart, Vita Enamic, 3M Lava Ultimate) in 1-, 1.5-, and 2-mm thicknesses. The samples were sliced at a pressure of 100 N with a low-speed precision cutting device under water cooling. The specimens were placed over a neutral grey background for initial spectrophotometric measurements. A three-color posterior nanohybrid composite (14x7x1 mm) was preferred to mimic discoloration in the substructure. The cementation procedure of the composite and the CAD/CAM hybrid ceramic complex was standardized under 10 N continuous pressure and was performed using a dual-cured resin cement. All samples were incubated at 37°C for 24 hours after cementation. The second spectrophotometric measurement was done via the L*, a*, and b* color attributes of the complex specimens. Additionally, ΔE* values were calculated to determine the color differences between each group. A Kruskal Wallis test was used for statistical analysis, and a Dunn’s test was used for group comparison. Significance was evaluated at p<0.05. Results: It was found that as the thickness of the ceramics increased, the substructure color was better masked, the thickness making a statistically significant difference in the masking ability (p<0.01). For 1- mm-thick samples, the highest ΔE* value was found in in Lava Ultimate (11.59) while the lowest value was found in GC Cerasmart (4.27). Conclusion: Within the limitations of this study, it was concluded that the tested CAD/CAM hybrid ceramics showed better masking ability than Cerec blocs. en_US
dc.identifier.endpage 120 en_US
dc.identifier.issn 2146-1767
dc.identifier.issue 2 en_US
dc.identifier.scopusquality N/A
dc.identifier.startpage 114 en_US
dc.identifier.trdizinid 482268
dc.identifier.uri https://search.trdizin.gov.tr/en/yayin/detay/482268/evaluating-the-masking-ability-of-cadcam-hybrid-ceramics-with-different-thicknesses
dc.identifier.uri https://hdl.handle.net/20.500.14720/9341
dc.identifier.volume 11 en_US
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.relation.ispartof International Dental Research en_US
dc.relation.publicationcategory Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Diş Hekimliği en_US
dc.title Evaluating the Masking Ability of Cad/Cam Hybrid Ceramics With Different Thicknesses en_US
dc.type Article en_US
dspace.entity.type Publication

Files