YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Pre-Heating Effect on the Microhardness and Depth of Cure of Bulk-Fill Composite Resins

dc.authorscopusid 57203147745
dc.authorscopusid 57222106520
dc.contributor.author Değirmenci, A.
dc.contributor.author Can, D.B.
dc.date.accessioned 2025-05-10T16:54:11Z
dc.date.available 2025-05-10T16:54:11Z
dc.date.issued 2022
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp Değirmenci A., Faculty of Dentistry, Department of Restorative Dentistry, Faculty of Dentistry, University of Van Yuzuncu Yil, Van, Turkey; Can D.B., Faculty of Dentistry, Department of Restorative Dentistry, Faculty of Dentistry, University of Van Yuzuncu Yil, Van, Turkey en_US
dc.description.abstract The aim of this study was to investigate the effect of preheating three bulk-fill and one conventional composite resin on the Vickers microhardness and depth of cure of these composites. In this study, three bulk-fill composites-SDR Plus (SDR), Estelite BULK FILL Flow (EST), Admira® Fusion x-tra (AFX), and one conventional composite resin G-ænial POSTERIOR (GP) were used as the control group. The samples were obtained at room temperature (24°C) and at 55°C in T2 mode after being placed in a heating device for 10 minutes. The samples were divided into eight groups (n=10) according to the type of material and heating process that was utilized (preheated and nonheated). All samples were tested with a Vickers microhardness (VHN) tester on the bottom and top surfaces. The first measurements were obtained at baseline; the second set of measurements was performed after the samples were stored in distilled water at 37°C for 24 hours. The depth of cure was calculated using a bottom/ top hardness ratio of measurements. Statistical analysis was performed utilizing the SPSS V23 and Shapiro-Wilk tests. Lastly, the Duncan test was used for multiple comparisons (p<0.05). While the VHN increased after the preheating procedure in bulk-fill composites, it decreased in GP. There was no difference between the baseline and the 24-hour VHN values in SDR and GP. After 24 hours, while the VHN of EST increased, the VHN of AFX decreased. There was no difference between the hardness ratios of the AFX and EST samples (p<0.001) and hardness ratios were greater than GP and SDR. When comparing the baseline and the 24-hour values, the VHN depended on the type of materials. Sufficient curing depth was obtained in all groups with a thickness of 2mm. © 2022, Universidad de Costa Rica. All rights reserved. en_US
dc.identifier.doi 10.15517/IJDS.2021.47209
dc.identifier.endpage 112 en_US
dc.identifier.issn 1659-1046
dc.identifier.issue 1 en_US
dc.identifier.scopus 2-s2.0-85129757262
dc.identifier.scopusquality Q3
dc.identifier.startpage 99 en_US
dc.identifier.uri https://doi.org/10.15517/IJDS.2021.47209
dc.identifier.uri https://hdl.handle.net/20.500.14720/3036
dc.identifier.volume 24 en_US
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher Universidad de Costa Rica en_US
dc.relation.ispartof Odovtos - International Journal of Dental Sciences en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Bulk-Fill Composite en_US
dc.subject Depth Of Cure en_US
dc.subject Microhybrid Composite en_US
dc.subject Ormocer en_US
dc.subject Preheating en_US
dc.subject Vickers Microhardness en_US
dc.title Pre-Heating Effect on the Microhardness and Depth of Cure of Bulk-Fill Composite Resins en_US
dc.type Article en_US

Files