YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Some Microbiological and Physicochemical Properties of Drinking Water in Bitlis District

dc.authorid Kahraman, Tahir/0000-0003-4238-8528
dc.authorwosid Kahraman, Tahi̇r/Aat-5781-2020
dc.contributor.author Alemdar, Sueleyman
dc.contributor.author Kahraman, Tahir
dc.contributor.author Agaoglu, Sema
dc.contributor.author Alisarli, Mustafa
dc.date.accessioned 2025-05-10T17:18:10Z
dc.date.available 2025-05-10T17:18:10Z
dc.date.issued 2009
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Alemdar, Sueleyman; Agaoglu, Sema; Alisarli, Mustafa] Yuzuncu Yil Univ, Veteriner Fak, Besin Hijyeni & Teknol ABD, TR-65080 Kampus, Van, Turkey; [Kahraman, Tahir] Pendik Veteriner Kontrol & Arastirma Enstitusu, TR-34890 Istanbul, Turkey en_US
dc.description Kahraman, Tahir/0000-0003-4238-8528 en_US
dc.description.abstract In the present study, microbiological and physicochemical qualities of drinking water obtained from the city of Bitlis and its provinces Adilcevaz, Ahlat, Guroymak, Hizan and Tatvan) were studied. A total of 164 water samples, collected from tank and tap waters in spring and autumn, were used as material. Aerobic plate counts were carried out by pour plate technique. While membrane filtration method was used for the counts of enterococcus, co iform, E. coli and sulphite reducing anaerobic bacteria and standard methods were recruited for physicochemical analysis. The results of physicochemical analysis of water samples were found to be in conformity with the standard regulations. Microbiological results of water, however, did not comply with required standards since the findings showed 30% enterococci, 12% coliform, 24% sulphite reducing anaerobic and 8% E. coli. The mean values of pH, Na and Mg, and presence of bacteria except E. coli were higher in autumn than spring. Effect of residential areas on aerobic plate count, coliform and E. coli were found to be insignificant (p>0.05), the effects on all other variables were found to be significant (p<0.05). en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.5053/ekoloji.2009.734
dc.identifier.endpage 38 en_US
dc.identifier.issn 1300-1361
dc.identifier.issue 73 en_US
dc.identifier.scopusquality N/A
dc.identifier.startpage 29 en_US
dc.identifier.uri https://doi.org/10.5053/ekoloji.2009.734
dc.identifier.uri https://hdl.handle.net/20.500.14720/9593
dc.identifier.volume 19 en_US
dc.identifier.wos WOS:000272330300004
dc.identifier.wosquality N/A
dc.language.iso tr en_US
dc.publisher Foundation Environmental Protection & Research-fepr en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Bitlis en_US
dc.subject Microbiological en_US
dc.subject Physicochemical en_US
dc.subject Water Pollution en_US
dc.title Some Microbiological and Physicochemical Properties of Drinking Water in Bitlis District en_US
dc.type Article en_US

Files