YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Long Coronary Artery Aneurysm Treated by Two Graft Stents on a Single Bare Metal Stent Scaffold

dc.authorid Gumrukcuoglu, Hasan Ali/0000-0002-5972-9870
dc.contributor.author Karapinar, Hekim
dc.contributor.author Kucukdurmaz, Zekeriya
dc.contributor.author Gumrukcuoglu, Hasan Ali
dc.contributor.author Yilmaz, Ahmet
dc.date.accessioned 2025-05-10T16:48:15Z
dc.date.available 2025-05-10T16:48:15Z
dc.date.issued 2012
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Karapinar, Hekim; Kucukdurmaz, Zekeriya; Yilmaz, Ahmet] Cumhuriyet Univ, Dept Cardiol, Fac Med, TR-58140 Sivas, Turkey; [Gumrukcuoglu, Hasan Ali] Van High Specialty Educ & Res Hosp, Dept Cardiol, Van, Turkey en_US
dc.description Gumrukcuoglu, Hasan Ali/0000-0002-5972-9870 en_US
dc.description.abstract We report a case of a 61-year-old male who presented with symptoms of stable angina The coronary angiography revealed a long aneurysm and significant stenosis after the aneurysmatic segment on the circumflex artery. The length of the aneurysm was 21 mm with the largest diameter 9 mm. We thought that single graft stent placement was not possible due to the angled circumflex artery, length of the aneurysm and inflexible nature of graft stents. Distal stenosis was stented as usual. A bare metal stent was implanted over the aneurysm from normal to normal segments. Two graft stents were implanted sequentially in the aneurysm over the bare metal stent scaffold. Stent grafts covered the aneurysm without any main side branch occlusion. The patient was discharged the next day without any complications. The patient was asymptomatic after two years of follow-up with usual medications. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.5114/pwki.2012.29662
dc.identifier.endpage 180 en_US
dc.identifier.issn 1734-9338
dc.identifier.issue 2 en_US
dc.identifier.scopusquality Q3
dc.identifier.startpage 179 en_US
dc.identifier.uri https://doi.org/10.5114/pwki.2012.29662
dc.identifier.uri https://hdl.handle.net/20.500.14720/1500
dc.identifier.volume 8 en_US
dc.identifier.wos WOS:000306728300017
dc.identifier.wosquality Q4
dc.language.iso en en_US
dc.publisher Termedia Publishing House Ltd en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Coronary Artery Aneurysm en_US
dc.subject Percutaneous Coronary Intervention en_US
dc.subject Stent Graft en_US
dc.title Long Coronary Artery Aneurysm Treated by Two Graft Stents on a Single Bare Metal Stent Scaffold en_US
dc.type Article en_US

Files