Synthesis of Au Nanoparticles Supported on Functionalized Silica Gel for Amperometric Determination of Hydrogen Peroxide in Contact Lens Solution
dc.contributor.advisor | Güler, Muhammet | |
dc.contributor.author | Bayram, Lütfullah | |
dc.date.accessioned | 2025-05-10T20:10:31Z | |
dc.date.available | 2025-05-10T20:10:31Z | |
dc.date.issued | 2019 | |
dc.department | Fen Bilimleri Enstitüsü / Kimya Ana Bilim Dalı / Biyokimya Bilim Dalı | |
dc.description.abstract | Bu çalışmada, kontakt lens çözeltisinde H2O2'nin elektrokimyasal olarak tayin edilebilmesi için (3-Aminopropil)trietoksisilan (APTES) ile fonksiyonel hale getirilmiş SiO2 destekli Au nanoparçacıklarına (Au@SiO2-APTES) dayalı yeni bir nanokompozit elde edilmiştir. Nafyon (Nf) koruyucu membran olarak kullanılmıştır. Au@SiO2-APTES ve SiO2-APTES kompozitleri ile modifiye edilmiş camsı karbon elektrodun (GCE) elektrokimyasal özellikleri, Elektrokimyasal impedans spektrokopisi (EIS), Dönüşümlü voltametri (CV) ve amperometri kullanılarak değerlendirilmiştir. Nanokompozitlerin karakterizasyonu için X-ışını difraksiyonu (XRD), Geçirimli elektron mikroskobu (TEM) ve Fourier transform infrared spektroskopisi (FTIR) kullanılmıştır. Elde edilen Nf/Au@SiO2-APTES/GCE sensörü H2O2 için iki doğrusal tayin aralığı göstermiştir. Birinci tayin aralığı 14-180 µM ve ikinci tayin aralığı 0.18-7.15 mM olarak belirlendi. Sensörün gözlenebilme sınırı (LOD) ve duyarlılıkları sırasıyla 4.75 µM, 2514.6 µA mM-1 cm-2 ve 894.2 µA mM-1 cm-2 olarak hesaplanmıştır. Sensör H2O2 için mükemmel seçicilik göstermiş ayrıca Nf/Au@SiO2-APTES/GCE kullanılarak kontakt lens çözeltisinde H2O2 başarılı bir şekilde tayin edilmiştir. | |
dc.description.abstract | In this study, a new nanocomposite based on (3-aminopropyl)triethoxysilane (APTES) functionalized SiO2 supported Au nanoparticles (Au@SiO2-APTES) was achieved for electroanalytical determintion of H2O2 in contact lens solution. Nafion (Nf) was performed as a protective membrane. The electrochemical properties of GCE modified with Au@SiO2-APTES and SiO2-APTES were evaluated by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and amperometry. X-ray diffraction (XRD), transmission electron microscopy (TEM), and fourier transform infrared spectroscopy (FTIR) were used for characterization of the nanocomposites. The obtained Nf/Au@SiO2-APTES/GCE sensor exhibited two linear determination ranges for H2O2. The first one was 14-180 µM and the second one was 0.18-7.15 mM. The limit of detection (LOD) and sensitivities of the sensor were calculated to be 4.25 µM, 2514.6 µA mM-1 cm-2 and 894.2 µA mM-1 cm-2, respectively. The sensor showed excellent selectivity for H2O2. Also, H2O2 was successfully detected in contact lens solution using Nf/Au@SiO2-APTES/GCE. | en_US |
dc.identifier.endpage | 99 | |
dc.identifier.uri | https://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=Mir2lXQK1dkmQ9Ige3PZbljGTn1F-zZyJeKxNdKMOGMKIl2OwX5zZvIOy01lP9Xm | |
dc.identifier.uri | https://hdl.handle.net/20.500.14720/22183 | |
dc.identifier.yoktezid | 555905 | |
dc.language.iso | tr | |
dc.subject | Kimya | |
dc.subject | Chemistry | en_US |
dc.title | Synthesis of Au Nanoparticles Supported on Functionalized Silica Gel for Amperometric Determination of Hydrogen Peroxide in Contact Lens Solution | en_US |
dc.title.alternative | Kontakt Lens Çözeltisindeki Hidrojen Peroksitin Amperometrik Olarak Tayin Edilmesi için Fonksiyonel Silika Jel Destekli Au Nanoparçacıkların Sentezlenmesi | en_US |
dc.type | Master Thesis | en_US |