YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Numerical Analysis With Experimental Comparison in Duct Flow Using Optimized Heat Sinks

dc.authorid Yakut, Ridvan/0000-0002-4145-7280
dc.authorid Karabey, Altug/0000-0001-5799-4585
dc.authorwosid Yakut, Ridvan/Kog-0635-2024
dc.authorwosid Karabey, Altug/S-3937-2018
dc.authorwosid Yesildal, Faruk/W-7760-2019
dc.authorwosid Yakut, Ridvan/Abe-1529-2020
dc.contributor.author Guresci, Kumru
dc.contributor.author Yesildal, Faruk
dc.contributor.author Karabey, Altug
dc.contributor.author Yakut, Ridvan
dc.contributor.author Yakut, Kenan
dc.date.accessioned 2025-05-10T17:04:36Z
dc.date.available 2025-05-10T17:04:36Z
dc.date.issued 2018
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Guresci, Kumru] Uludag Univ, Dept Mech Engn, Inst Nat Sci, TR-16120 Bursa, Turkey; [Yesildal, Faruk] Ibrahim Cecen Univ Agri, Fac Engn, Dept Mech Engn, TR-04100 Agri, Turkey; [Karabey, Altug] Yuzuncu Yil Univ, Ercis Vocat High Sch, Dept Machinery & Met Technol, TR-65400 Van, Turkey; [Yakut, Ridvan] Kafkas Univ, Fac Engn & Architecture, Dept Mech Engn, TR-36100 Kars, Turkey; [Yakut, Kenan] Ataturk Univ, Fac Engn, Dept Mech Engn, TR-25100 Erzurum, Turkey en_US
dc.description Yakut, Ridvan/0000-0002-4145-7280; Karabey, Altug/0000-0001-5799-4585 en_US
dc.description.abstract In many industrial applications, heat must be transferred in the form of either an energy input into the system or removal of energy produced in the system. In this study, heat transfer and flow characteristics of hexagonal finned heat sinks which optimized according to the Taguchi experimental L-18(2(1)*3(7)) design method in channel flow was analyzed numerically. Ansys-Fluent Icepak module was used in CFD analysis. The analysis carried out for two hexagonal finned optimized heat sinks in 3 different fin heights and 5 different flow velocities. Nusselt number increased with increasing Reynolds number for OH-1 and OH-2 heat sinks with all fin heights. Also, results showed that the friction factor decreased with increasing Reynolds number for all fin heights. According to CFD results, Nu-Re and f-Re variations were obtained and compared with experimental results. The experimental results and the numerical results were quite consistent. (c) 2017 The Egyptian Society of Radiation Sciences and Applications. Production and hosting by Elsevier B.V. en_US
dc.description.sponsorship Ataturk University, Research Project Foundation [BAP-2011/408] en_US
dc.description.sponsorship This work was supported by Ataturk University, Research Project Foundation (project number BAP-2011/408). en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1016/j.jrras.2017.10.008
dc.identifier.endpage 123 en_US
dc.identifier.issn 1687-8507
dc.identifier.issue 2 en_US
dc.identifier.scopusquality N/A
dc.identifier.startpage 116 en_US
dc.identifier.uri https://doi.org/10.1016/j.jrras.2017.10.008
dc.identifier.uri https://hdl.handle.net/20.500.14720/6067
dc.identifier.volume 11 en_US
dc.identifier.wos WOS:000432446700002
dc.identifier.wosquality Q3
dc.language.iso en en_US
dc.publisher Taylor & Francis Ltd en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Finned Heat Sink en_US
dc.subject Electronic Cooling Systems en_US
dc.subject Computational Fluid Dynamics (Cfd) en_US
dc.title Numerical Analysis With Experimental Comparison in Duct Flow Using Optimized Heat Sinks en_US
dc.type Article en_US

Files