YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Carbon Nano Tube Assisted Triple Metal Electrode and High-Impact Electro Sensor for Preservative Detection in Food Samples

dc.authorscopusid 57207255717
dc.authorscopusid 57189211902
dc.authorscopusid 25959155500
dc.contributor.author Yayla, M.
dc.contributor.author Çelik Kazıcı, H.
dc.contributor.author Kivrak, H.D.
dc.date.accessioned 2025-05-10T16:55:18Z
dc.date.available 2025-05-10T16:55:18Z
dc.date.issued 2024
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp Yayla M., Department of Chemistry and Chemical Processing Technologies, Muradiye Vocational School, Van Yüzüncü Yıl University, Van, Turkey; Çelik Kazıcı H., Department of Chemistry, Faculty of Science, Van Yüzüncü Yıl University, Van, Turkey; Kivrak H.D., Department of Chemical Engineering, Faculty of Engineering, Eskişehir Osmangazi University, Eskisehir, Turkey en_US
dc.description.abstract In this study, the electrode surface was modified with ternary metal supported by carbon nanotubes and for this purpose, PdRuCr-based sensor was developed that determines the preservatives in different food. The surfaces electronic and chemical properties were determined by methods such as SEM-EDX (scanning electron microscopy, Energy-Emitting X-ray analysis) and XRD (X ray diffraction). The activities of the electrocatalyzers were carried out using electrochemical measurements such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods. The lowest limit ranges (LOD) were determined. For benzoic acid (BA) and potassium sorbate (PS), the specification limit values of the sensors were calculated as 0.82 µM (0.1 mgL−1 in ppm) and and 11.9 µM (1.78 mgL−1 in ppm) respectively. The sensitivity of the sensor was calculated as 1123,944 µA/mM.cm2 for BA and 2363,38 µA/mM.cm2 for PS and linear concentration range were determined as 2.5–200 µM for BA and 35–140 µM for PS, respectively. © 2023 Informa UK Limited, trading as Taylor & Francis Group. en_US
dc.identifier.doi 10.1080/14328917.2023.2280864
dc.identifier.endpage 320 en_US
dc.identifier.issn 1432-8917
dc.identifier.issue 5 en_US
dc.identifier.scopus 2-s2.0-85178101715
dc.identifier.scopusquality Q2
dc.identifier.startpage 309 en_US
dc.identifier.uri https://doi.org/10.1080/14328917.2023.2280864
dc.identifier.uri https://hdl.handle.net/20.500.14720/3437
dc.identifier.volume 28 en_US
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher Taylor and Francis Ltd. en_US
dc.relation.ispartof Materials Research Innovations en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Benzoic Acid en_US
dc.subject Food Sensor en_US
dc.subject Potassium Sorbate en_US
dc.title Carbon Nano Tube Assisted Triple Metal Electrode and High-Impact Electro Sensor for Preservative Detection in Food Samples en_US
dc.type Article en_US

Files