YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Can Computerized Tomography Hounsfield Unit Values Be Useful in the Differential Diagnosis of Pleural Effusion

dc.authorscopusid 56690325400
dc.authorscopusid 54998741200
dc.authorscopusid 55041924700
dc.authorscopusid 57189044570
dc.authorscopusid 36993622000
dc.contributor.author Durmaz, F.
dc.contributor.author Ozgokce, M.
dc.contributor.author Ayyildiz, V.A.
dc.contributor.author Cilingir, B.M.
dc.contributor.author Goya, C.
dc.date.accessioned 2025-05-10T17:02:27Z
dc.date.available 2025-05-10T17:02:27Z
dc.date.issued 2020
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp Durmaz F., Department of Radiology, Hakkari State Hospital, Hakkari, Turkey; Ozgokce M., Department of Radiology, Van Yuzuncu Yıl University School of Medicine, Van, Turkey; Ayyildiz V.A., Department of Radiology, Suleyman Demirel University School of Medicine, Isparta, Turkey; Cilingir B.M., Department of Chest Diseases, Van Yuzuncu Yıl University School of Medicine, Van, Turkey; Goya C., Department of Radiology, Van Yuzuncu Yıl University School of Medicine, Van, Turkey en_US
dc.description.abstract Introduction: We aimed to investigate the efficacy of Hounsfield unit (HU) attenuation measured on computed tomography (CT) as a non-invasive method for pleural effusion characterization. Methods: Patients with pleural effusion who underwent thoracic CT imaging and thoracentesis within a maximum of three days were included in this retrospective study (15 transudate and 36 exudate). By drawing a circular region of interest (ROI) on the section with the thickest pleural effusion in terms of anteroposterior diameter in the upper-medial-lower zone on axial images, a total of three HU values, one from each level, were averaged. An independent t-test was applied to the CT attenuation (HU) values for the transudate-exudate differentiation. A receiver operating characteristic (ROC) analysis was then made. Results: The mean attenuation±standard deviation (minimum-maximum) value for the patients with transudate was 2.17±3.76 ((-7.5)-7.5) HU, whereas the mean HU value for the patients with exudate was 8.38±6.2 ((-6)-22). The independent t test made for the transudate-exudate differentiation revealed a statistically significant difference (P=0.001). In the ROC analysis carried out to determine the cut-off value of the attenuation value of pleural effusion in the transudate-exudate differentiation, the area under the curve was found to be 82.8%. When the cut-off value was taken as 2.75HU for the area under the curve, sensitivity was found to be 84%, and specificity was 60%. Conclusion: Although CT-HU values are statistically significant in the differential diagnosis of transudate-exudate, there is still a need to establish a correlation with other tomographic findings and clinical laboratory findings. © 2020 The Author(s). en_US
dc.identifier.doi 10.34172/jrcm.2020.026
dc.identifier.issn 2717-0616
dc.identifier.scopus 2-s2.0-85134382741
dc.identifier.scopusquality Q4
dc.identifier.uri https://doi.org/10.34172/jrcm.2020.026
dc.identifier.uri https://hdl.handle.net/20.500.14720/5524
dc.identifier.volume 8 en_US
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher Tabriz University of Medical Sciences en_US
dc.relation.ispartof Journal of Research in Clinical Medicine en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Attenuation en_US
dc.subject Computed Tomography en_US
dc.subject Pleural Effusion en_US
dc.subject Transudates, Exudates en_US
dc.title Can Computerized Tomography Hounsfield Unit Values Be Useful in the Differential Diagnosis of Pleural Effusion en_US
dc.type Article en_US