YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Comparıson of Pulse Oxymeter and Cerebral Oxymeter Values in Healthy Newborns in the First Five Mınutes of Life

dc.authorscopusid 26030126400
dc.authorscopusid 26531350600
dc.authorscopusid 26531767700
dc.authorscopusid 35243692700
dc.authorscopusid 26025132600
dc.authorscopusid 56186063400
dc.authorscopusid 56186063400
dc.contributor.author Taskin, G.A.
dc.contributor.author Kaya, A.
dc.contributor.author Sal, E.
dc.contributor.author Üstyol, L.
dc.contributor.author Peker, E.
dc.contributor.author Tuncer, O.
dc.contributor.author Kırımi, E.
dc.date.accessioned 2025-05-10T16:43:21Z
dc.date.available 2025-05-10T16:43:21Z
dc.date.issued 2014
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp Taskin G.A., Yüzüncü Yıl University, Department of Pediatrics, Van, Turkey; Kaya A., Yüzüncü Yıl University, Department of Pediatrics, Van, Turkey; Sal E., Yüzüncü Yıl University, Department of Pediatrics, Van, Turkey; Üstyol L., Yüzüncü Yıl University, Department of Pediatrics, Van, Turkey; Peker E., Yüzüncü Yıl University, Department of Neonatalogy, Van, Turkey; Tuncer O., Yüzüncü Yıl University, Department of Neonatalogy, Van, Turkey; Kırımi E., Yüzüncü Yıl University, Department of Neonatalogy, Van, Turkey en_US
dc.description.abstract Objective: Practical approaches in delivery rooms have been discussed about oxygen usage in recent years. In this study, it was aimed to correlate preductal arterial oxygen saturation (SpO2), heart rate per minute and serebral oxygen saturation (SbO2) values of first five minutes of life and to try the pulse oxymeter (PO) and cerebral oxymeter (SO) usage practice in delivery room. Material and Method: A hundred healthy term uncomplicated newborn babies, who were born via normally spontan vaginal route, were included in the study. SpO2, SbO2, heart rate measurements and blood gase analysis of first five minutes of postnatal life were completed. Babies, who needed oxygen during measurements, were not taken in to the study.. Results: While postnatal 1st minute SpO2 value was 83.0±4.4 (74-94)%; at 5th minute these measurements reached to 92.9±3.5 (85-98)% with gradually increment. Except values of 4th and 5th minutes; SpO2 values were found statistically significant high with each other (p<0.05). At SbO2 measurements, suitable data was taken from 100% of the babies in first minute of life. While postnatal mean SbO2 value of the first minute was 48.9±9.9 (32-74)%; these measurements were reached to 69.9±9.5 (46-89)% at 5th minute gradually increment as like as SpO2 values. Conclusion: SO is complementary to PO in delivery room and can be used routinely. It was seen also in our study; oxygen need of newborns can be determined faster and more accurately with SO use in delivery room so unnecessary oxygen usage and its potential risks can be avoided.. © 2015, Nobelmedicus. All Rights Reserved. en_US
dc.identifier.endpage 75 en_US
dc.identifier.issn 1305-2381
dc.identifier.issue 1 en_US
dc.identifier.scopus 2-s2.0-84927766902
dc.identifier.scopusquality Q4
dc.identifier.startpage 71 en_US
dc.identifier.uri https://hdl.handle.net/20.500.14720/135
dc.identifier.volume 11 en_US
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher Nobelmedicus en_US
dc.relation.ispartof Nobel Medicus en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Cerebral Oxymeter en_US
dc.subject Delivery Room en_US
dc.subject Monitoring en_US
dc.subject Newborn en_US
dc.title Comparıson of Pulse Oxymeter and Cerebral Oxymeter Values in Healthy Newborns in the First Five Mınutes of Life en_US
dc.type Article en_US

Files