Intraoperative Repair of Pilot Balloon Inflation Line Damage: A Practical Solution to Tube Replacement

dc.contributor.author Güneş, H.Y.
dc.contributor.author Aydın, A.
dc.date.accessioned 2025-11-30T19:17:48Z
dc.date.available 2025-11-30T19:17:48Z
dc.date.issued 2025
dc.description.abstract Intraoperative damage to the pilot balloon inflation line of an endotracheal tube (ETT) can result in cuff deflation, leading to ineffective ventilation and increased aspiration risk. This case report describes a practical repair technique that allowed continued saf e ventilation without tube replacement. A 70-year-old woman underwent elective coronary artery bypass grafting. During central venous catheter placement, the anesthesia machine displayed low etCO₂ and ventilator failure alarms. Diminished bilateral breath sounds were noted, and the pilot balloon was found severed. As the patient's hemodynamics remained stable, a 20G intravenous catheter steel needle t ip was inserted directly into the inflation line, carefully positioned to avoid further damage. The cuff was reinflated using a syringe, and appropriate pressure was maintained with a three-way stopcock and cuff manometer. The air leak resolved, and surgery proceeded without requiring tube exchange. Pilot balloon damage can be safely managed intraoperatively using readily available equipment. This practical approach may serve as a valuable alternative to endotracheal tube replacement, especially in cases involving a difficult airw ay. Familiarity with such repair methods can enhance airway safety during surgery. en_US
dc.identifier.doi 10.5505/VMJ.2025.46320
dc.identifier.issn 1300-2694
dc.identifier.issn 2587-0351
dc.identifier.scopus 2-s2.0-105021220861
dc.identifier.uri https://doi.org/10.5505/VMJ.2025.46320
dc.identifier.uri https://hdl.handle.net/20.500.14720/29083
dc.language.iso en en_US
dc.publisher Yuzuncu Yil Universitesi Tip Fakultesi en_US
dc.relation.ispartof Van Medical Journal en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Airway Management en_US
dc.subject Cuff Inflation Line Repair en_US
dc.subject Cut Pilot Balloon en_US
dc.subject Endotracheal Tube en_US
dc.subject Intraoperative Complication en_US
dc.title Intraoperative Repair of Pilot Balloon Inflation Line Damage: A Practical Solution to Tube Replacement en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.scopusid 55569995300
gdc.author.scopusid 60178227300
gdc.coar.access open access
gdc.coar.type text::journal::journal article
gdc.description.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
gdc.description.departmenttemp [Güneş] Haci Yusuf, Department of Anesthesiology, Van Yüzüncü Yıl Üniversitesi, Van, Turkey; [Aydın] Aslan, Department of Anesthesiology, Van Yüzüncü Yıl Üniversitesi, Van, Turkey en_US
gdc.description.endpage 342 en_US
gdc.description.issue 4 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality N/A
gdc.description.startpage 339 en_US
gdc.description.volume 32 en_US
gdc.description.wosquality N/A
gdc.index.type Scopus

Files