Simple and Sensitive Electrochemical Determination of Higenamine in Dietary Supplements Using a Disposable Pencil Graphite Electrode

dc.authorid Senturk, Zuhre/0000-0002-0356-9345
dc.authorid Yardim, Yavuz/0000-0002-9587-096X
dc.authorscopusid 55807475500
dc.authorscopusid 55511747958
dc.authorscopusid 7004177719
dc.authorwosid Senturk, Zuhre/Aas-5179-2020
dc.authorwosid Talay Pınar, Pınar/Jfj-2292-2023
dc.contributor.author Pinar, Pinar Talay
dc.contributor.author Yardim, Yavuz
dc.contributor.author Senturk, Zuhre
dc.date.accessioned 2025-05-10T17:04:13Z
dc.date.available 2025-05-10T17:04:13Z
dc.date.issued 2020
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Pinar, Pinar Talay; Yardim, Yavuz] Van Yuzuncu Yil Univ, Fac Pharm, Dept Analyt Chem, TR-65080 Van, Turkey; [Senturk, Zuhre] Van Yuzuncu Yil Univ, Fac Sci, Dept Analyt Chem, TR-65080 Van, Turkey en_US
dc.description Senturk, Zuhre/0000-0002-0356-9345; Yardim, Yavuz/0000-0002-9587-096X en_US
dc.description.abstract In this study, a cheap, rapid, simple, and modification-free electroanalytical methodology based on the disposable pencil graphite electrode is described for the quantification of higenamine (isoquinoline-type alkaloid having three phenolic OHs). At first, the electrochemical oxidation of higenamine was investigated in aqueous solutions by cyclic voltammetry. The electrode process is pH-dependent and controlled by a mixture of diffusion and adsorption processes. Higenamine yielded two well-separated oxidation steps in acidic, neutral, and alkaline media by using square-wave voltammetry. By using the first oxidation peak due to its higher sensitivity, there was an excellent correlation between oxidation peak current at + 0.44 V and higenamine concentration (as hydrochloride salt) in the range of 0.05 to 2.0 mu g cm(-3) (1.63 x 10(-7)-6.5 x 10(-6) mol dm(-3)), with a detection limit of 0.014 mu g cm(-3) (4.55 x 10(-8) mol dm(-3)) in Britton-Robinson buffer at pH 4.0. As an example, the developed approach can be used for the quantification of higenamine in the commercial dietary supplement formulations. Graphic abstract en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1007/s00706-020-02556-y
dc.identifier.endpage 307 en_US
dc.identifier.issn 0026-9247
dc.identifier.issn 1434-4475
dc.identifier.issue 3 en_US
dc.identifier.scopus 2-s2.0-85079451020
dc.identifier.scopusquality Q2
dc.identifier.startpage 301 en_US
dc.identifier.uri https://doi.org/10.1007/s00706-020-02556-y
dc.identifier.uri https://hdl.handle.net/20.500.14720/5951
dc.identifier.volume 151 en_US
dc.identifier.wos WOS:000513059000001
dc.identifier.wosquality Q3
dc.language.iso en en_US
dc.publisher Springer Wien en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Higenamine en_US
dc.subject Pencil Graphite Electrode en_US
dc.subject Square-Wave Voltammetry en_US
dc.subject Dietary Supplements en_US
dc.title Simple and Sensitive Electrochemical Determination of Higenamine in Dietary Supplements Using a Disposable Pencil Graphite Electrode en_US
dc.type Article en_US
dspace.entity.type Publication

Files