YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Voltammetric Sensing of Triclosan in the Presence of Cetyltrimethylammonium Bromide Using a Cathodically Pretreated Boron-Doped Diamond Electrode

dc.authorid Yardim, Yavuz/0000-0002-9587-096X
dc.authorid Senturk, Zuhre/0000-0002-0356-9345
dc.authorscopusid 55511747958
dc.authorscopusid 57193907843
dc.authorscopusid 7004177719
dc.authorwosid Senturk, Zuhre/Aas-5179-2020
dc.contributor.author Yardim, Yavuz
dc.contributor.author Alpar, Nurcan
dc.contributor.author Senturk, Zuhre
dc.date.accessioned 2025-05-10T17:44:01Z
dc.date.available 2025-05-10T17:44:01Z
dc.date.issued 2018
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Yardim, Yavuz; Alpar, Nurcan] Van Yuzuncu Yil Univ, Dept Analyt Chem, Fac Pharm, Van, Turkey; [Senturk, Zuhre] Van Yuzuncu Yil Univ, Dept Analyt Chem, Fac Sci, Van, Turkey en_US
dc.description Yardim, Yavuz/0000-0002-9587-096X; Senturk, Zuhre/0000-0002-0356-9345 en_US
dc.description.abstract In the present study, a simple, cheap and sensitive electrochemical method based on a cathodically pretreated boron-doped diamond (CPT-BDD) electrode is described for the detection of triclosan with the cationic surfactant (cetyltrimethylammonium bromide, CTAB) media. The oxidation of triclosan was irreversible and exhibited an adsorption controlled process. The sensitivity of the adsorptive stripping voltammetric measurements was significantly improved with addition of CTAB. Using square-wave stripping mode, a linear response was obtained for triclosan determination in Britton-Robinson buffer solution at pH 9.0 containing 2.5 x 10(-4) M CTAB at around + 0.67 V (vs. Ag/AgCl) (after 30 s accumulation at open-circuit condition). The method could be used in the range of 0.01-1.0 mu g mL(-1) (3.5 x 10(-8)-3.5 x 10(-6) M), with a detection limit of 0.0023 mu g mL(-1) (7.9 x 10(-9) M). The feasibility of the proposed method for the determination of triclosan in water samples was checked in spiked tap water. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1080/03067319.2018.1537395
dc.identifier.endpage 1241 en_US
dc.identifier.issn 0306-7319
dc.identifier.issn 1029-0397
dc.identifier.issue 13 en_US
dc.identifier.scopus 2-s2.0-85055566573
dc.identifier.scopusquality Q2
dc.identifier.startpage 1226 en_US
dc.identifier.uri https://doi.org/10.1080/03067319.2018.1537395
dc.identifier.uri https://hdl.handle.net/20.500.14720/16049
dc.identifier.volume 98 en_US
dc.identifier.wos WOS:000451132200004
dc.identifier.wosquality Q3
dc.language.iso en en_US
dc.publisher Taylor & Francis Ltd en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Triclosan en_US
dc.subject Voltammetry en_US
dc.subject Cathodically Pretreated Boron-Doped Diamond en_US
dc.subject Cetyltrimethylammonium Bromide en_US
dc.title Voltammetric Sensing of Triclosan in the Presence of Cetyltrimethylammonium Bromide Using a Cathodically Pretreated Boron-Doped Diamond Electrode en_US
dc.type Article en_US

Files