YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

The Comparison of Dose Distribution of Different 3d Conformal and Conventional Radiotherapy Plans for Gastric Cancer

dc.authorscopusid 56069278500
dc.authorscopusid 56146786600
dc.authorscopusid 35775027600
dc.authorscopusid 35775325600
dc.authorscopusid 56286748400
dc.authorwosid Çakır, Tahir/Jac-4161-2023
dc.contributor.author Izmirli, M.
dc.contributor.author Yilmazer, G.
dc.contributor.author Cakir, T.
dc.contributor.author Palabiyik, Z. A.
dc.contributor.author Nart, M.
dc.date.accessioned 2025-05-10T17:42:00Z
dc.date.available 2025-05-10T17:42:00Z
dc.date.issued 2016
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Izmirli, M.; Yilmazer, G.; Cakir, T.; Palabiyik, Z. A.; Nart, M.] Yuzuncu Yil Univ, Sch Med, Dept Radiat Oncol, TR-65080 Van, Turkey en_US
dc.description.abstract Aims: It was aimed to investigate postoperative conformal radiotherapy planning that provides the best target volume and the least dose for critical organs in cancers of stomach. Methods: This study was conducted on the CT simulation images of thirty patients diagnosed with gastric cancer. Target volumes and the organs at risk were contoured. AP-PA reciprocal parallel field conventional plan and three- and four-field 3D conformal plans were created using linear accelerator. Target volumes and doses consumed by organs at risk were compared by dose-volume histograms. Results: While a sufficient dose could be applied to target volumes in all plans with conformal planning, average figures showed that 95% of porta hepatis area failed to take the prescribed dose (D95) in some plans by using AP-PA reciprocal parallel zone conventional plans. The most convenient protection for spinal cord, heart and kidneys was obtained by conformal four-field technique and the liver doses were increased in conformal four-field plans but did not exceed the tolerance dose. And also, in the conventional AP-PA reciprocal parallel field plans, tolerance dose of spinal cord (4500 cGy) was exceeded. Conclusion: In this study, conformal four-field technique was superior considering target volume dose distributions, and especially spinal cord doses in all localizations and heart doses in cardia tumors. Kidney doses were also reduced in conformal four-field planning, but failed to reach statistical significance. There was a not exceeding tolerance limits dose increase in liver. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.18869/acadpub.ijrr.143.197
dc.identifier.endpage 203 en_US
dc.identifier.issn 2322-3243
dc.identifier.issue 3 en_US
dc.identifier.scopus 2-s2.0-84990928280
dc.identifier.scopusquality Q4
dc.identifier.startpage 197 en_US
dc.identifier.uri https://doi.org/10.18869/acadpub.ijrr.143.197
dc.identifier.uri https://hdl.handle.net/20.500.14720/15424
dc.identifier.volume 14 en_US
dc.identifier.wos WOS:000391053200005
dc.identifier.wosquality Q4
dc.language.iso en en_US
dc.publisher Ijrr-iranian Journal Radiation Res en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Gastric Cancer en_US
dc.subject 3-Dimensional Conformal Radiotherapy en_US
dc.subject Dose-Volume Histogram en_US
dc.title The Comparison of Dose Distribution of Different 3d Conformal and Conventional Radiotherapy Plans for Gastric Cancer en_US
dc.type Article en_US

Files