YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

A New Approach for the Voltammetric Sensing of the Phytoestrogen Genistein at a Non-Modified Boron-Doped Diamond Electrode

dc.authorid Ali, Hoshyar/0000-0002-9138-485X
dc.authorid Barzani, Hemn Abdulazeez Hakeem/0000-0002-1875-7760
dc.authorid Yardim, Yavuz/0000-0002-9587-096X
dc.authorscopusid 57220154278
dc.authorscopusid 57434945400
dc.authorscopusid 57434804700
dc.authorscopusid 57434945500
dc.authorscopusid 55511747958
dc.authorwosid Ali, Hoshyar/Aay-8463-2021
dc.contributor.author Barzani, Hemn A. H.
dc.contributor.author Ali, Hoshyar Saadi
dc.contributor.author Sahin, Cihat
dc.contributor.author Kiran, Musa
dc.contributor.author Yardim, Yavuz
dc.date.accessioned 2025-05-10T17:37:05Z
dc.date.available 2025-05-10T17:37:05Z
dc.date.issued 2022
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Barzani, Hemn A. H.; Ali, Hoshyar Saadi] Van Yuzuncu Yil Univ, Fac Sci, Dept Analyt Chem, TR-65080 Van, Turkey; [Barzani, Hemn A. H.] Aynda Private Tech Inst, Dept Pharm, Erbil 44001, Iraq; [Ali, Hoshyar Saadi] Knowledge Univ, Coll Sci, Dept Med Lab Sci, Kirkuk 44001, Erbil, Iraq; [Sahin, Cihat; Kiran, Musa; Yardim, Yavuz] Van Yuzuncu Yil Univ, Fac Pharm, Dept Analyt Chem, TR-65080 Van, Turkey en_US
dc.description Ali, Hoshyar/0000-0002-9138-485X; Barzani, Hemn Abdulazeez Hakeem/0000-0002-1875-7760; Yardim, Yavuz/0000-0002-9587-096X en_US
dc.description.abstract An effective electrochemical sensor was constructed using an unmodified boron-doped diamond electrode for determination of genistein by square-wave voltammetry. Cyclic voltammetric investigations of genistein with HClO4 solution indicated that irreversible behavior, adsorption-controlled and well-defined two oxidation peaks at about +0.92 (P-A1) & +1.27 V (P-A2). pH, as well as supporting electrolytes, are important in genistein oxidations. Quantification analyses of genistein were conducted using its two oxidation peaks. Using optimized experiments as well as instrumental conditions, the current response with genistein was proportionately linear in the concentrations range of 0.1 to 50.0 mu g mL(-1) (3.7x10(-7)-1.9x10(-4) mol L-1), by the detection limit of 0.023 mu g mL(-1) (8.5x10(-8) mol L-1) for P-A1 and 0.028 mu g mL(-1) (1.1x10(-7) mol L-1) for P-A2 in 0.1 mol L-1 HClO4 solution (in the open circuit condition at 30 s accumulation time). Ultimately, the developed method was effectively applied to detect genistein in model human urine samples by using its second oxidation peak (P-A2). en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1002/elan.202100608
dc.identifier.endpage 1288 en_US
dc.identifier.issn 1040-0397
dc.identifier.issn 1521-4109
dc.identifier.issue 8 en_US
dc.identifier.scopus 2-s2.0-85123855396
dc.identifier.scopusquality Q2
dc.identifier.startpage 1280 en_US
dc.identifier.uri https://doi.org/10.1002/elan.202100608
dc.identifier.uri https://hdl.handle.net/20.500.14720/14275
dc.identifier.volume 34 en_US
dc.identifier.wos WOS:000748162100001
dc.identifier.wosquality Q2
dc.language.iso en en_US
dc.publisher Wiley-v C H verlag Gmbh en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Genistein en_US
dc.subject Boron-Doped Diamond Electrode en_US
dc.subject Square-Wave Voltammetry en_US
dc.subject Urine Samples en_US
dc.title A New Approach for the Voltammetric Sensing of the Phytoestrogen Genistein at a Non-Modified Boron-Doped Diamond Electrode en_US
dc.type Article en_US

Files