YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

First Report for the Electrochemical Investigation of a New Hiv Integrase Inhibitor Dolutegravir: Its Voltammetric Determination in Tablet Dosage Forms and Human Urine Using a Boron-Doped Diamond Electrode

dc.authorid Yardim, Yavuz/0000-0002-9587-096X
dc.authorscopusid 57210193426
dc.authorscopusid 55807475500
dc.authorscopusid 55511747958
dc.authorscopusid 7004177719
dc.authorwosid Senturk, Zuhre/Aas-5179-2020
dc.authorwosid Talay Pınar, Pınar/Jfj-2292-2023
dc.contributor.author Allahverdiyeva, Shabnam
dc.contributor.author Pinar, Pinar Talay
dc.contributor.author Yardim, Yavuz
dc.contributor.author Senturk, Zuhre
dc.date.accessioned 2025-05-10T17:09:47Z
dc.date.available 2025-05-10T17:09:47Z
dc.date.issued 2021
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Allahverdiyeva, Shabnam] Van Yuzuncu Yil Univ, Fac Sci, Dept Biochem, TR-65080 Van, Turkey; [Pinar, Pinar Talay; Yardim, Yavuz] Van Yuzuncu Yil Univ, Fac Pharm, Dept Analyt Chem, TR-65080 Van, Turkey; [Senturk, Zuhre] Van Yuzuncu Yil Univ, Fac Sci, Dept Analyt Chem, TR-65080 Van, Turkey en_US
dc.description Yardim, Yavuz/0000-0002-9587-096X en_US
dc.description.abstract In this paper, for the first time, the study of electrochemical investigation and voltammetric determination of HIV integrase inhibitor dolutegravir was described. The effect of pretreatment (anodically or cathodically) of borondoped diamond electrode was investigated in detail on the stripping voltammetric performance for this compound. Dolutegravir presented one or two oxidation peaks within the pH range 2.0-12.0 by using both pretreated electrodes. Employing square-wave stripping mode on the surface of cathodically pretreated boron-doped diamond electrode (after 60 s accumulation at +0.3 V) in Britton-Robinson buffer at pH 10.0, there was a linear dependence of the peak current at +0.79 V (vs. Ag/AgCl, 3 M NaCl) and dolutegravir concentration in the range of 1.0-50.0 mu g mL(-1) (2.38 x 10(-6) -1.19 x 10(-4) M), with a detection limit of 0.26 mu g mL(-1) (6.20 x 10(-7) M). The applicability of the developed approach for the quantification of dolutegravir was tested in the commercial tablet formulations and model human urine samples. en_US
dc.description.sponsorship Scientific Research Projects Coordination Unit (BAP) of Van Yuzuncu Yil Univer-sity, Turkey [FBA-2019-7630] en_US
dc.description.sponsorship The authors gratefully acknowledge the support of the Scientific Research Projects Coordination Unit (BAP) of Van Yuzuncu Yil Univer-sity, Turkey (Project number: FBA-2019-7630) . en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1016/j.diamond.2021.108332
dc.identifier.issn 0925-9635
dc.identifier.issn 1879-0062
dc.identifier.scopus 2-s2.0-85101920986
dc.identifier.scopusquality Q2
dc.identifier.uri https://doi.org/10.1016/j.diamond.2021.108332
dc.identifier.uri https://hdl.handle.net/20.500.14720/7226
dc.identifier.volume 114 en_US
dc.identifier.wos WOS:000687963100004
dc.identifier.wosquality Q2
dc.language.iso en en_US
dc.publisher Elsevier Science Sa en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Dolutegravir en_US
dc.subject Boron-Doped Diamond Electrode en_US
dc.subject Square-Wave Adsorptive Stripping Voltammetry en_US
dc.subject Tablets en_US
dc.subject Urine en_US
dc.title First Report for the Electrochemical Investigation of a New Hiv Integrase Inhibitor Dolutegravir: Its Voltammetric Determination in Tablet Dosage Forms and Human Urine Using a Boron-Doped Diamond Electrode en_US
dc.type Article en_US