YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Comparison of Conformal Radiotherapy, Intensity-Modulated Radiotherapy and Tomotherapy Irradiation Techniques in Prostate Cancers

dc.authorid Koylu, Murat/0000-0003-0439-8768
dc.authorid Tugrul, Taylan/0000-0002-0557-1334
dc.authorscopusid 57197793142
dc.authorscopusid 47561912700
dc.authorscopusid 55764077500
dc.authorwosid Olacak, Nezahat/Lzg-3304-2025
dc.authorwosid Tuğrul, Taylan/D-4372-2017
dc.authorwosid Köylü, Murat/D-3507-2017
dc.contributor.author Tugrul, Taylan
dc.contributor.author Olacak, Nezahat
dc.contributor.author Koylu, Murat
dc.date.accessioned 2025-05-10T17:25:46Z
dc.date.available 2025-05-10T17:25:46Z
dc.date.issued 2019
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Tugrul, Taylan] Yuzuncu Yil Univ, Fac Med, Dept Radiat Oncol, Van, Turkey; [Olacak, Nezahat; Koylu, Murat] Ege Univ, Fac Med, Dept Radiat Oncol, Izmir, Turkey en_US
dc.description Koylu, Murat/0000-0003-0439-8768; Tugrul, Taylan/0000-0002-0557-1334 en_US
dc.description.abstract Aim The aim of this study is to compare three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT) and tomotherapy techniques used in the treatment of prostate cancer with target and critical organ doses to be included. Materials and Methods The target dose was studied with 4-and 6-field 3D-CRT, 7-field IMRT and tomotherapy techniques used to treat ten patients for prostate cancer and the dose volume histograms of critical organs were analyzed. The same target volumes, critical organs doses prescribed and treatment times for the three techniques were compared. Total dose of 76 Gy was given using 6 MV and 18 MV for 3D-CRT, 6 MV for IMRT and tomotherapy techniques. Results When we compare the three techniques, for rectum V-35(p:0 center dot 001), V-65(p:0 center dot 001), D-50(p:0 center dot 020) and D-25(p:0 center dot 002), for bladder V-50(p:0 center dot 027), V-65(p:0 center dot 006), V-100(p:0 center dot 006) and for femoral head, the V-50(p:0 center dot 001) dose was found to be significantly different and more favourable in the tomotherapy technique. Significant differences were found with IMRT planning in 50% of bladder volume (p:0 center dot 002). There is no significant difference between the three techniques for doses of 100% volume of rectum and 25% of volume of bladder. The minimum dose that healthy tissue received which was outside the tumour volume was investigated. Findings Doses to critical organs were lower using the tomotherapy technique. However, the minimum doses that healthy tissue received were higher for the tomotherapy technique. When the beam on times were compared for all three techniques, a significant difference was found in favor of tomotherapy. en_US
dc.description.woscitationindex Emerging Sources Citation Index
dc.identifier.doi 10.1017/S1460396918000766
dc.identifier.endpage 279 en_US
dc.identifier.issn 1460-3969
dc.identifier.issn 1467-1131
dc.identifier.issue 3 en_US
dc.identifier.scopus 2-s2.0-85061995780
dc.identifier.scopusquality Q4
dc.identifier.startpage 276 en_US
dc.identifier.uri https://doi.org/10.1017/S1460396918000766
dc.identifier.uri https://hdl.handle.net/20.500.14720/11471
dc.identifier.volume 18 en_US
dc.identifier.wos WOS:000477899800010
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher Cambridge Univ Press en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject 3D-Crt en_US
dc.subject Imrt en_US
dc.subject Prostate Cancer en_US
dc.subject Radiotherapy en_US
dc.subject Tomotherapy en_US
dc.title Comparison of Conformal Radiotherapy, Intensity-Modulated Radiotherapy and Tomotherapy Irradiation Techniques in Prostate Cancers en_US
dc.type Article en_US

Files