YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Design and Simulation of Active Direct Current Filter for High Voltage Direct Current Transmission Systems

dc.authorid Genc, Naci/0000-0001-5673-1708
dc.authorid Akdemir, Murat/0000-0001-9235-1913
dc.authorscopusid 57193685898
dc.authorscopusid 23480878900
dc.authorscopusid 23481908900
dc.authorwosid Akdemi̇r, Murat/A-8506-2017
dc.authorwosid Genc, Naci/Aae-3477-2019
dc.contributor.author Akdemir, Murat
dc.contributor.author Yildirim, Selcuk
dc.contributor.author Genc, Naci
dc.date.accessioned 2025-05-10T17:39:22Z
dc.date.available 2025-05-10T17:39:22Z
dc.date.issued 2016
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Akdemir, Murat; Yildirim, Selcuk] Siirt Univ, Muhendislik Mimarlik Fak, Elekt Elekt Muhendisligi Bolumu, Siirt, Turkey; [Genc, Naci] Yuzuncu Yil UNiv, Muhendislik Mimarlik Fak, Elekt Elekt Muhendisligi Bolumu, Van, Turkey en_US
dc.description Genc, Naci/0000-0001-5673-1708; Akdemir, Murat/0000-0001-9235-1913 en_US
dc.description.abstract In this paper, firstly, a monopolar High Voltage Direct Current (HVDC) transmission system model has been formed. Series, parallel and series-parallel active direct current filter designs were carried out to suppress harmonics caused by the converters in this HVDC transmission system. Simulations of the designed HVDC transmission system using these filter were carried out in MATLAB Simulink. Waveforms and total harmonic distortion (THD) values of load current and voltage were obtained in this transmission system model for filtered and unfiltered conditions. Harmonics in the load voltage and current were suppressed to a large extent by active direct current filter used in the HVDC transmission system. Furthermore, THD values for current and voltage were obtained significantly below 5%. According to these results, designed active direct current filters which have simple structure and not complex controller offer significant advantages. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.17341/gazimmfd.278462
dc.identifier.endpage 1083 en_US
dc.identifier.issn 1300-1884
dc.identifier.issn 1304-4915
dc.identifier.issue 4 en_US
dc.identifier.scopus 2-s2.0-85018711703
dc.identifier.scopusquality Q3
dc.identifier.startpage 1073 en_US
dc.identifier.uri https://doi.org/10.17341/gazimmfd.278462
dc.identifier.uri https://hdl.handle.net/20.500.14720/14870
dc.identifier.volume 31 en_US
dc.identifier.wos WOS:000392927000026
dc.identifier.wosquality Q4
dc.language.iso tr en_US
dc.publisher Gazi Univ, Fac Engineering Architecture en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Active Direct Current Filter en_US
dc.subject Harmonics en_US
dc.subject High Voltage Direct Current en_US
dc.title Design and Simulation of Active Direct Current Filter for High Voltage Direct Current Transmission Systems en_US
dc.type Article en_US

Files