Investigation of Skin Dose of Post-Mastectomy Radiation Therapy for the Halcyon and Tomotherapy Treatment Machine: Comparison of Calculation and in Vivo Measurements

dc.authorid Gul, Osman Vefa/0000-0002-6773-3132
dc.authorid Demir, Hikmettin/0000-0002-1171-4821
dc.authorscopusid 57193453129
dc.authorscopusid 57220369315
dc.authorscopusid 58223343200
dc.authorwosid Gul, Osman Vefa/Aaf-2848-2021
dc.authorwosid Demir, Hikmettin/Hga-7385-2022
dc.contributor.author Demir, Hikmettin
dc.contributor.author Gul, Osman Vefa
dc.contributor.author Aksu, Telat
dc.date.accessioned 2025-05-10T17:23:46Z
dc.date.available 2025-05-10T17:23:46Z
dc.date.issued 2024
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Demir, Hikmettin] Van Yuzuncu Yil Univ, Fac Med, Dept Radiat Oncol, Van, Turkiye; [Gul, Osman Vefa] Selcuk Univ, Fac Med, Dept Radiat Oncol, Konya, Turkiye; [Aksu, Telat] Ondokuz Mayis Univ, Fac Med, Dept Radiat Oncol, Samsun, Turkiye en_US
dc.description Gul, Osman Vefa/0000-0002-6773-3132; Demir, Hikmettin/0000-0002-1171-4821 en_US
dc.description.abstract In treatments such as post-mastectomy radiation therapy (PMRT) for breast cancer patients, skin doses are of great importance in terms of tumor control and side effects. This dosimetric study aimed to measure the skin dose on the chest wall surface for post-mastectomy radiotherapy with Tomotherapy and Halcyon devices using thermoluminescence dosimetry (TLD) and to evaluate the accuracy of the skin dose calculated by treatment planning systems (TPS). Computed tomography (CT) images of the Alderson Rando phantom were obtained. Treatment plans were created with Tomotherapy and Halycon devices for a total of 50 Gy with a fraction dose of 2 Gy to the target volume. The left chest wall was divided into 9 regions for detailed surface dose assessment. 88 dose measurement points were determined on the left chest wall. The phantom was irradiated separately in Halycon and Tomotherapy devices. In vivo, dose measurements were performed with TLD in both devices. TPS and TLD doses were compared for the left chest wall surface. For skin dose, TLD measurements were lower than the dose estimate by Tomotherapy TPS and higher than the dose estimate by Halycon TPS. In addition, the skin dose measurements showed that the skin dose of the Tomotherapy device was higher than that of the Halycon. It is recommended to consider the distance of the treatment device and the accuracy of the TPS dose calculation in skin dose assessment in PMRT. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1016/j.radmeas.2024.107112
dc.identifier.issn 1350-4487
dc.identifier.issn 1879-0925
dc.identifier.scopus 2-s2.0-85189445913
dc.identifier.scopusquality Q2
dc.identifier.uri https://doi.org/10.1016/j.radmeas.2024.107112
dc.identifier.uri https://hdl.handle.net/20.500.14720/10997
dc.identifier.volume 173 en_US
dc.identifier.wos WOS:001223836400001
dc.identifier.wosquality Q2
dc.language.iso en en_US
dc.publisher Pergamon-elsevier Science Ltd en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Tomotherapy en_US
dc.subject Halycon en_US
dc.subject Breast Cancer en_US
dc.subject Skin Dose en_US
dc.subject Thermoluminescence Dosimetry (Tld) en_US
dc.title Investigation of Skin Dose of Post-Mastectomy Radiation Therapy for the Halcyon and Tomotherapy Treatment Machine: Comparison of Calculation and in Vivo Measurements en_US