Indoor Radon Measurement in Van
dc.authorid | Osmanlioglu, Ahmet/0000-0001-5547-7525 | |
dc.authorid | Osmanlioglu, Ahmet Erdal/0000-0002-5209-3769 | |
dc.authorscopusid | 57189083722 | |
dc.authorscopusid | 6506107091 | |
dc.authorscopusid | 16027693600 | |
dc.authorscopusid | 7003380938 | |
dc.authorwosid | Kam, Erol/Luw-7766-2024 | |
dc.authorwosid | Osmanlioglu, Ahmet/D-7843-2013 | |
dc.contributor.author | Kam, E. | |
dc.contributor.author | Osmanlioglu, A.E. | |
dc.contributor.author | Dogan, I. | |
dc.contributor.author | Celebi, N. | |
dc.date.accessioned | 2025-05-10T17:06:35Z | |
dc.date.available | 2025-05-10T17:06:35Z | |
dc.date.issued | 2007 | |
dc.department | T.C. Van Yüzüncü Yıl Üniversitesi | en_US |
dc.department-temp | Kam E., TAEK, Cekmece Nuclear Research and Training Center, Istanbul, Turkey; Osmanlioglu A.E., TAEK, Cekmece Nuclear Research and Training Center, Istanbul, Turkey; Dogan I., Yuzuncu Yil University, Faculty of Veterinary Medicine, Biochemistry Department, Van, Turkey; Celebi N., TAEK, Cekmece Nuclear Research and Training Center, Istanbul, Turkey | en_US |
dc.description.abstract | In this study, indoor radon concentrations obtained from the radon surveys conducted in the Van. Radon monitoring was performed by applying a passive, time-integrating measuring technique. For this purpose, CR-39 nuclear track detectors were installed in dwellings for 2 months. After the monitoring period, detectors were collected. In order to make the alpha tracks visible, chemical etching was applied to the exposed detectors. Nuclear track numbers and the corresponding indoor radon concentrations were determined. Annual effective dose equivalents and the risk probabilities caused by indoor radon inhalation were calculated, and the found results compared with the indoor radon concentrations' data measured in different provinces of Turkey. © 2007 American Institute of Physics. | en_US |
dc.description.woscitationindex | Conference Proceedings Citation Index - Science | |
dc.identifier.doi | 10.1063/1.2733477 | |
dc.identifier.issn | 1551-7616 | |
dc.identifier.scopus | 2-s2.0-34547454291 | |
dc.identifier.scopusquality | Q4 | |
dc.identifier.startpage | 736 | en_US |
dc.identifier.uri | https://doi.org/10.1063/1.2733477 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14720/6478 | |
dc.identifier.volume | 899 | en_US |
dc.identifier.wos | WOS:000246647900450 | |
dc.identifier.wosquality | N/A | |
dc.language.iso | en | en_US |
dc.relation.ispartof | AIP Conference Proceedings -- 6TH International Conference of the Balkan Physical Union -- 22 August 2006 through 26 August 2007 -- Istanbul | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Cr-39 Detector | en_US |
dc.subject | Indoor Radon | en_US |
dc.subject | Radon | en_US |
dc.subject | Van | en_US |
dc.title | Indoor Radon Measurement in Van | en_US |
dc.type | Conference Object | en_US |