YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Out-Of Behavior of Dry-Stack Brick Masonry Walls

dc.authorscopusid 36720357400
dc.authorscopusid 58546633200
dc.authorscopusid 24077426800
dc.authorwosid Erdil, Baris/Lxv-9472-2024
dc.contributor.author Erdil, Baris
dc.contributor.author Kipcak, Firat
dc.contributor.author Tapan, Muecip
dc.date.accessioned 2025-05-10T17:18:06Z
dc.date.available 2025-05-10T17:18:06Z
dc.date.issued 2024
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Erdil, Baris; Tapan, Muecip] Van Yuzuncu Yil Univ, Civil Engn Dept, Van, Turkiye; [Kipcak, Firat] Van Yuzuncu Yil Univ, Vocat Sch Van, Cons Tech Dept, Van, Turkiye en_US
dc.description.abstract As a result of the combination of the complex behavior of masonry buildings with insufficient material quality and lack in engineering calculations, a large number of damages has been observed in the earthquakes that occurred in recent years. Therefore, a realistic understanding of the behavior of masonry walls and buildings is necessary to construct seismic-resistant structures. Since masonry walls have many variables, performing experiments in which each variable is present at the same time will make it difficult to understand the behavior. For these reasons, considering the out-of-plane failures that are frequently mentioned in recent earthquakes, in this study, variables in dry-stack brick masonry buildings such as the aspect ratio of the wall (2, 1.33, and 1), the presence of the transverse walls (2, 1, and 0), and the openings in the walls (door and/or window) were taken into account separately. Eighteen different wall configurations were designed, and a total of 48 dry-stack walls having U-shape, L-shape, and I-shape in plan were tested by a specially constructed tilting table setup to determine their out-of-plane behavior. From the test results, it was found that lateral load capacity of the U-shaped walls without openings increased as the aspect ratio (L/H) decreased. No change in capacity was observed in L- and I-shaped walls when the aspect ratio was reduced from 2 to 1. Door and/or window openings were found to affect only the L-shaped walls. In addition, it was determined that failure patterns were affected from the aspect ratio and the presence of the openings. en_US
dc.description.sponsorship VAN YUZUNCU YIL UNIVERSITY; Scientific and Technological Research Council of Turkey (TUBITAK) [117M316]; [FDP-2018-7209] en_US
dc.description.sponsorship The authors wish to express sincere appreciation to the Scientific and Technological Research Council of Turkey (TUBITAK) (Project No: 117M316) and Van Yuzuncu Yil University (FDP-2018-7209) for financing this research program. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1002/tal.2089
dc.identifier.issn 1541-7794
dc.identifier.issn 1541-7808
dc.identifier.issue 5 en_US
dc.identifier.scopus 2-s2.0-85179371179
dc.identifier.scopusquality Q2
dc.identifier.uri https://doi.org/10.1002/tal.2089
dc.identifier.uri https://hdl.handle.net/20.500.14720/9568
dc.identifier.volume 33 en_US
dc.identifier.wos WOS:001123497400001
dc.identifier.wosquality Q3
dc.language.iso en en_US
dc.publisher Wiley en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Brick en_US
dc.subject Dry-Stack en_US
dc.subject Load-Displacement en_US
dc.subject Openings en_US
dc.subject Out-Of-Plane en_US
dc.subject Transverse Wall en_US
dc.title Out-Of Behavior of Dry-Stack Brick Masonry Walls en_US
dc.type Article en_US