YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

The Comparison of Brain and Lens Doses in Whole Brain Radiotherapy With Different Treatment Plannings

dc.authorscopusid 24072601900
dc.authorscopusid 56069278500
dc.authorscopusid 35775325600
dc.authorscopusid 35775027600
dc.contributor.author Ugurluer, Gamze
dc.contributor.author Izmirli, Mustafa
dc.contributor.author Palamik, Zehra A.
dc.contributor.author Cakir, Tahir
dc.date.accessioned 2025-05-10T17:46:35Z
dc.date.available 2025-05-10T17:46:35Z
dc.date.issued 2009
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Ugurluer, Gamze; Izmirli, Mustafa; Palamik, Zehra A.; Cakir, Tahir] Yuzuncu Yil Univ, Tip Fak, Radyasyon Onkol Anabilim Dali, TR-65100 Van, Turkey en_US
dc.description.abstract The aim of study was to evaluate the effects ontarget volume (brain) and lens doses with different treatment plannings in patients who received whole brain radiotherapy because of brain metastases. The system tomography scans of 14 patients at 0.5 cm intervals, were transferred to three-dimensional treatment planning computer and the normal tissues and target volumes were outlined. Seven different treatment plannings were done for each patient. Plan I: Angled blocked plan; Plan II: Non-angled blocked plan; Plan III: Helmet plan; Plan IV: Blocked plan with the inferior border at the inferior orbital ridge; Plan V: Angled unblocked plan; Plan VI: Non-angled unblocked plan; Plan VII: Conventially planned non-angled unblocked plan. Brain and lens minimum, maximum and mean doses and brain V95 and D95 doses were recorded for each plan using dose-volume histograms. When the plans were compared according to the brain minimum, mean, V95 and D95 doses, it was observed that the doses in Plan VII were lower than the others (mean 1171.57 cGy, mean 3294.64 cGy, 97.48% and mean 2990.57 cGy respectively, p < 0.05). When the plans were compared according to the lens doses, the minimum, maximum and mean doses were higher in the unblocked plans (p < 0.05). It was seen that with the angling of beams five degrees to the posterior the lens doses decreased (p < 0.05). This study shows that using 3 dimensional treatment planning, brain minimum doses increases and the dose inhomogenity decreases, and lens doses decreases using customized blocks and angling of beams five degrees posteriorly. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.endpage 146 en_US
dc.identifier.issn 1306-133X
dc.identifier.issue 3 en_US
dc.identifier.scopus 2-s2.0-72949111818
dc.identifier.scopusquality Q4
dc.identifier.startpage 140 en_US
dc.identifier.uri https://hdl.handle.net/20.500.14720/16742
dc.identifier.volume 19 en_US
dc.identifier.wos WOS:000271596100003
dc.identifier.wosquality Q4
dc.language.iso tr en_US
dc.publisher Akad Doktorlar Yayinevi en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Whole Brain Radiotherapy en_US
dc.subject Target Volume Doses en_US
dc.subject Lens Doses en_US
dc.title The Comparison of Brain and Lens Doses in Whole Brain Radiotherapy With Different Treatment Plannings en_US
dc.type Article en_US

Files