Effects of Polishing Procedures on Optical Parameters and Surface Roughness of Composite Resins With Different Viscosities
dc.authorscopusid | 57203147745 | |
dc.authorscopusid | 58165213400 | |
dc.authorscopusid | 57210176205 | |
dc.contributor.author | Degirmenci, A. | |
dc.contributor.author | Pehlivan, I.E. | |
dc.contributor.author | Unalan Degirmenci, B. | |
dc.date.accessioned | 2025-05-10T16:54:47Z | |
dc.date.available | 2025-05-10T16:54:47Z | |
dc.date.issued | 2023 | |
dc.department | T.C. Van Yüzüncü Yıl Üniversitesi | en_US |
dc.department-temp | Degirmenci A., Department of Restorative Dentistry, Faculty of Dentistry, University of Van Yuzuncu Yil, Van, Turkey; Pehlivan I.E., Department of Restorative Dentistry, Faculty of Dentistry, University of Van Yuzuncu Yil, Van, Turkey; Unalan Degirmenci B., Department of Prosthodontics, Faculty of Dentistry, University of Van Yuzuncu Yil, Van, Turkey | en_US |
dc.description.abstract | The aims of this study were to evaluate the optical properties of flowable and injectable composites after polishing, such as translucency (translucency parameter [TP], TP00), opalescence (OP-BW), chroma (C*ab), refractive index (RI), and change in surface roughness (Ra, Rz). Ninety disc-shaped samples were prepared from micro-hybrid, flowable, and injectable composites and divided into 3 groups according to the polishing systems (n=10). The RI was measured with an Abbe refractometer, and optical measurements were performed with a spectrophotometer. The surface roughness was measured with a two-dimensional profilometer. Data were analyzed with the generalized linear model method and two-way analysis of variance. The results showed that the polishing procedure did not significantly impact the RI (p=0.987). Injectable composite had the highest translucency (TP=28.67; TP00=13.49) and opalescence (OP-BW=13.11); showed the lowest C*ab value (17.95). Also, the effects of the composite type and polishing procedure on surface roughness were statistically significant (p=0.047 and p<0.001). © 2023, Japanese Society for Dental Materials and Devices. All rights reserved. | en_US |
dc.identifier.doi | 10.4012/dmj.2022-178 | |
dc.identifier.endpage | 210 | en_US |
dc.identifier.issn | 0287-4547 | |
dc.identifier.issue | 2 | en_US |
dc.identifier.pmid | 36476685 | |
dc.identifier.scopus | 2-s2.0-85151312963 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 199 | en_US |
dc.identifier.uri | https://doi.org/10.4012/dmj.2022-178 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14720/3255 | |
dc.identifier.volume | 42 | en_US |
dc.identifier.wosquality | Q3 | |
dc.language.iso | en | en_US |
dc.publisher | Japanese Society for Dental Materials and Devices | en_US |
dc.relation.ispartof | Dental Materials Journal | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Composite Resins | en_US |
dc.subject | Opalescence | en_US |
dc.subject | Refractive Index | en_US |
dc.subject | Surface Roughness | en_US |
dc.subject | Translucency | en_US |
dc.title | Effects of Polishing Procedures on Optical Parameters and Surface Roughness of Composite Resins With Different Viscosities | en_US |
dc.type | Article | en_US |