Square-Wave Adsorptive Stripping Voltammetric Determination of Hesperidin Using a Boron-Doped Diamond Electrode
dc.authorid | Senturk, Zuhre/0000-0002-0356-9345 | |
dc.authorid | Yardim, Yavuz/0000-0002-9587-096X | |
dc.authorscopusid | 57216838945 | |
dc.authorscopusid | 55511747958 | |
dc.authorscopusid | 7004177719 | |
dc.authorwosid | Senturk, Zuhre/Aas-5179-2020 | |
dc.contributor.author | Yigit, Aydin | |
dc.contributor.author | Yardim, Yavuz | |
dc.contributor.author | Senturk, Zuhre | |
dc.date.accessioned | 2025-05-10T17:04:32Z | |
dc.date.available | 2025-05-10T17:04:32Z | |
dc.date.issued | 2020 | |
dc.department | T.C. Van Yüzüncü Yıl Üniversitesi | en_US |
dc.department-temp | [Yigit, Aydin; Yardim, Yavuz] Yuzuncu Yil Univ, Fac Pharm, Dept Analyt Chem, Van 65080, Turkey; [Senturk, Zuhre] Yuzuncu Yil Univ, Fac Sci, Dept Analyt Chem, Van 65080, Turkey | en_US |
dc.description | Senturk, Zuhre/0000-0002-0356-9345; Yardim, Yavuz/0000-0002-9587-096X | en_US |
dc.description.abstract | In the present study, an electroanalytical method for the determination of hesperidin using adsorptive stripping voltammetry at an unmodified boron-doped diamond (BDD) electrode is presented. In cyclic voltammetry, the compound showed one irreversible and adsorption-controlled oxidation peak, resulting in the formation of a couple with a reduction and re-oxidation wave at less positive potentials. Using square-wave stripping mode, the observed anodic peak current in 0.1 M perchloric acid solution at +0.90 V (vs. Ag/AgCl) (after 30 s accumulations at a fixed potential of +0.4 V) increased linearly from 2.5 to 70 mu g/mL (4.09 x 10(-6)-1.15 x 10(-4) M). A detection limit of 0.7 mu g/mL (1.2 x 10(-6) M) and relative standard deviation of 8.2% for the concentration of 2.5 mu g/mL (n = 10) were observed. To evaluate the practical applicability of the BDD electrode, it was used for the quantification of hesperidin in the commercial dietary supplement formulations. | en_US |
dc.description.woscitationindex | Science Citation Index Expanded | |
dc.identifier.doi | 10.1134/S1061934820050184 | |
dc.identifier.endpage | 661 | en_US |
dc.identifier.issn | 1061-9348 | |
dc.identifier.issn | 1608-3199 | |
dc.identifier.issue | 5 | en_US |
dc.identifier.scopus | 2-s2.0-85084921137 | |
dc.identifier.scopusquality | Q3 | |
dc.identifier.startpage | 653 | en_US |
dc.identifier.uri | https://doi.org/10.1134/S1061934820050184 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14720/6041 | |
dc.identifier.volume | 75 | en_US |
dc.identifier.wos | WOS:000530804800014 | |
dc.identifier.wosquality | Q4 | |
dc.language.iso | en | en_US |
dc.publisher | Pleiades Publishing inc | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Hesperidin | en_US |
dc.subject | Boron-Doped Diamond Electrode | en_US |
dc.subject | Square-Wave Adsorptive Stripping Voltammetry | en_US |
dc.subject | Dietary Supplement | en_US |
dc.title | Square-Wave Adsorptive Stripping Voltammetric Determination of Hesperidin Using a Boron-Doped Diamond Electrode | en_US |
dc.type | Article | en_US |