YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Investigation of Radiological Properties of Imaging Agents Used in Nu Clear Med I Cine With Dif Fer Ent Meth Ods and Gate/Geant4 Sim U La Tion Pro Gram

dc.authorscopusid 55936291700
dc.authorscopusid 57197793142
dc.authorwosid Tuğrul, Taylan/D-4372-2017
dc.authorwosid Sahmaran, Turan/F-8155-2013
dc.contributor.author Sahmaran, Turan
dc.contributor.author Tugrul, Taylan
dc.date.accessioned 2025-05-10T17:21:17Z
dc.date.available 2025-05-10T17:21:17Z
dc.date.issued 2023
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Sahmaran, Turan] Hatay Mustafa Kemal Univ, Kirikhan Vocat Sch, Hatay, Turkiye; [Tugrul, Taylan] Van Yuzuncu Yil Univ, Fac Med, Dept Radiat Oncol, Van, Turkiye en_US
dc.description.abstract This study aims to determine the radiological properties of various radiopharmaceuticals used in nuclear medicine. In the study, mass attenuation coefficient values in different energy ranges were ob tained for six dif fer ent radiopharmaceuticals dimercaptosuccinic acid, diethylenetriamine pentaacetate, mercaptoacetyltriglycine, hexamethylpropyleneamine oxime, methoxyisobutylisonitrile, meth y lene diphosphate by us ing GATE sim u la tion pro gram, XCOM and WinXCom pro grams. Us ing these val ues, ef fec tive atomic num ber and elec tron den sity val ues were cal cu lated with the help of the di rect method, in ter po la tion method, Auto-Zeff soft ware, Phy-X/ZeXTra, XMuDat pro gram, and Mayneourd's for mula. In ad di tion, the ef fec tive atomic num ber and elec tron den sity val ues ob tained were com pared for each radiopharmaceutical, both among them selves and be tween the meth ods. When radiopharmaceuticals were com pared among them selves in low and high-en ergy re gions, the high est ef fec tive atomic num ber val ues were ob tained in dimercaptosuccinic acid, meth y lene diphosphate, and mercaptoacetyltriglycine. The mass attenuation coefficient values calculated us ing the GATE code in di cate that it is a suit able method for de ter min ing the mass at tenuation coefficient for imaging agents with no experimental values. This study indicates that the sim u la tion ge om e try method is suit able to be used as an al ter na tive method for the ex per i ments. In ad di tion, the val ues ob tained for these mol e cules used as radiopharmaceuticals were ex am ined for the first time. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.2298/NTRP2302116S
dc.identifier.endpage 124 en_US
dc.identifier.issn 1451-3994
dc.identifier.issn 1452-8185
dc.identifier.issue 2 en_US
dc.identifier.scopus 2-s2.0-85184218170
dc.identifier.scopusquality Q3
dc.identifier.startpage 116 en_US
dc.identifier.uri https://doi.org/10.2298/NTRP2302116S
dc.identifier.uri https://hdl.handle.net/20.500.14720/10360
dc.identifier.volume 38 en_US
dc.identifier.wos WOS:001126674500001
dc.identifier.wosquality Q3
dc.language.iso en en_US
dc.publisher Vinca inst Nuclear Sci en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Radiopharmaceuticals en_US
dc.subject Nu Clear Med I Cine en_US
dc.subject Ef Fec Tive Atomic Num Ber en_US
dc.subject Monte Carlo en_US
dc.title Investigation of Radiological Properties of Imaging Agents Used in Nu Clear Med I Cine With Dif Fer Ent Meth Ods and Gate/Geant4 Sim U La Tion Pro Gram en_US
dc.type Article en_US

Files