YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Development of an Ultra-Sensitive Method Using Nafion and Multi-Walled Carbon Nanotube Coated Glassy Carbon Electrode for Atenolol Determination

dc.contributor.author Celik Kazici, Hilal
dc.date.accessioned 2025-05-10T17:11:09Z
dc.date.available 2025-05-10T17:11:09Z
dc.date.issued 2018
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Celik Kazici, Hilal] Yuzuncu Yil Univ, Dept Chem Engn, Fac Engn, Van, Turkey en_US
dc.description.abstract Atenolol (Scheme 1) is antihypertensive drug that form beta-blocker group, which widely used in the treatment of hypertension In this study, the redox properties of the Tensinor drug used in blood pressure treatment were examined on modified glassy carbon electrode and the electrodes prepared by coating carbon nanotubes on this modified electrode. In order to investigate the effects of nafion coated multi-walled glass nanotube (MWCNT /NGCE) electrode response and nafion coated glassy carbon electrode (NGCE) and electrode responses of only glassy carbon electrode (GCE) surfaces on the support electrolyte, pH and scan rate, the cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods were used. Atenolol (ATN) was observed in the BrittonRobinson (BR) buffer solution (pH 7.0) thereabouts 1.11 V (vsAg / AgCl (3.0 mol L-1 KCl). Voltammetric method reacted linear at a concentration range between 3x10-5 mu M and 9x10-2 mu M under optimum analytical experimental conditions. The results of Tensinor's limit of detection on the Britton-Robinson (BR) (pH= 7) buffer were found to be 7.67 x 10-5 mM and 2.5 x 10-4 mM, respectively. Additionally, in the study, interference effects experiments were performed with auxiliary substances used in the preparation of medicines and no negative effect was observed. en_US
dc.description.sponsorship Scientic and Technological Research Council of Turkey (TUBITAK) [1919B011501676] en_US
dc.description.sponsorship This work was financially supported by Scientic and Technological Research Council of Turkey (TUBITAK) (Project No: 1919B011501676). en_US
dc.description.woscitationindex Emerging Sources Citation Index
dc.identifier.doi 10.5505/pajes.2017.54366
dc.identifier.endpage 1292 en_US
dc.identifier.issn 1300-7009
dc.identifier.issn 2147-5881
dc.identifier.issue 7 en_US
dc.identifier.scopusquality N/A
dc.identifier.startpage 1287 en_US
dc.identifier.uri https://doi.org/10.5505/pajes.2017.54366
dc.identifier.uri https://hdl.handle.net/20.500.14720/7656
dc.identifier.volume 24 en_US
dc.identifier.wos WOS:000453906100008
dc.identifier.wosquality N/A
dc.institutionauthor Celik Kazici, Hilal
dc.language.iso en en_US
dc.publisher Pamukkale Univ en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Cyclic Voltammetry en_US
dc.subject Atenolol en_US
dc.subject Carbon Nano Tube en_US
dc.title Development of an Ultra-Sensitive Method Using Nafion and Multi-Walled Carbon Nanotube Coated Glassy Carbon Electrode for Atenolol Determination en_US
dc.type Article en_US

Files