dc.description.abstract We describe a technique to manage dense cataract cases After a capsulorhexis of 6.0 to 7.0 mm diameter has been created, the phaco tip is inserted into the nucleus centrally and high vacuum is used to lift the nucleus and elevate it with a tilt to protrude outside the capsular bag distally The chopper is used to segment the nucleus centripetally, starting from the lens equator or just behind, without applying stress to the capsular bag or zonules Further phacoemulsification is maintained by holding the nucleus centrally and chopping it into smaller triangular sectoral pieces. In this horizontal chopping technique, which is done just outside the capsular bag, grasping the nucleus in the center and elevating it with high vacuum instead of depressing one edge of the nucleus to elevate the other edge prevents additional stress to the capsule and zonules. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1016/j.jcrs.2009.11.011
dc.identifier.endpage 541 en_US
dc.identifier.issn 0886-3350
dc.identifier.issn 1873-4502
dc.identifier.issue 4 en_US
dc.identifier.pmid 20362841
dc.identifier.scopusquality Q1
dc.identifier.startpage 539 en_US
dc.identifier.uri https://doi.org/10.1016/j.jcrs.2009.11.011
dc.identifier.uri https://hdl.handle.net/20.500.14720/1761
dc.identifier.volume 36 en_US
dc.identifier.wos WOS:000276785200002
dc.identifier.wosquality Q2
dc.language.iso en en_US
dc.publisher Elsevier Science inc en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.title Lift and Crack Technique for Risky Cataract Cases en_US
dc.type Article en_US

Files