Compressive Strength of Scoria Added Portland Cement Concretes
dc.authorid | Depci, Tolga/0000-0001-9562-8068 | |
dc.authorscopusid | 35739305500 | |
dc.authorscopusid | 24077426800 | |
dc.authorscopusid | 55321137200 | |
dc.authorscopusid | 55320549800 | |
dc.authorscopusid | 23767083500 | |
dc.authorwosid | Tapan, Mucip/Aak-7594-2020 | |
dc.authorwosid | Depci, Tolga/A-2867-2016 | |
dc.contributor.author | Ozvan, A. | |
dc.contributor.author | Tapan, M. | |
dc.contributor.author | Erik, O. | |
dc.contributor.author | Efe, T. | |
dc.contributor.author | Depci, T. | |
dc.date.accessioned | 2025-05-10T17:47:44Z | |
dc.date.available | 2025-05-10T17:47:44Z | |
dc.date.issued | 2012 | |
dc.department | T.C. Van Yüzüncü Yıl Üniversitesi | en_US |
dc.department-temp | [Ozvan, A.; Efe, T.; Depci, T.] Yuzuncu Yil Univ, Nat Resources Lake Basin Res & Applicat Ctr, Zeve Campus, TR-65080 Van, Turkey | en_US |
dc.description | Depci, Tolga/0000-0001-9562-8068 | en_US |
dc.description.abstract | This paper presents the results of preliminary studies investigating the potential effects of using scoria as supplementary and its amount on compressive strength of concrete. Concrete mixtures containing 5, 10, 20, 30, 40 and 50 % scoria type natural pozzolan by mass of the total cementitious material were prepared. In addition, a conventional portland cement concrete mixture with the same w/cm ratio was prepared as a reference. Preliminary results indicated that the compressive strength of the concrete mixtures with scoria added up to 30% exceeded the strength of the conventional mixture at 3, 7, 28 and 91 days, whereas the compressive strength of the 40 and 50% scoria added concrete mixtures decreased at 3, 7, 28 and 91 days. It was found that early strength of scoria added (up to 30%) concrete mixtures showed higher compressive strengths up to 112%. | en_US |
dc.description.sponsorship | Yuzuncu Yil University [2010-FBE-YL146] | en_US |
dc.description.sponsorship | This research is partially funded by Yuzuncu Yil University (Project Number : 2010-FBE-YL146). The authors would like to thank to Yuzuncu Yil University for their financial support. The authors also wish to thank Dr. Vural OYAN for his help, during sample collection and petrographical studies. | en_US |
dc.description.woscitationindex | Emerging Sources Citation Index | |
dc.identifier.endpage | 775 | en_US |
dc.identifier.issn | 2147-1762 | |
dc.identifier.issue | 3 | en_US |
dc.identifier.scopus | 2-s2.0-84864212593 | |
dc.identifier.scopusquality | Q3 | |
dc.identifier.startpage | 769 | en_US |
dc.identifier.uri | https://hdl.handle.net/20.500.14720/16868 | |
dc.identifier.volume | 25 | en_US |
dc.identifier.wos | WOS:000421140000025 | |
dc.identifier.wosquality | N/A | |
dc.language.iso | en | en_US |
dc.publisher | Gazi Univ | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Compressive Strength | en_US |
dc.subject | Porosity | en_US |
dc.subject | Scoria | en_US |
dc.subject | Structural Concrete | en_US |
dc.subject | Specific Surface Area | en_US |
dc.title | Compressive Strength of Scoria Added Portland Cement Concretes | en_US |
dc.type | Article | en_US |