Electroanalytical Determination of Enrofloxacin Based on the Enhancement Effect of the Anionic Surfactant at Anodically Pretreated Boron-Doped Diamond Electrode
No Thumbnail Available
Date
2018
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Elsevier Science Sa
Abstract
In this paper, a mercury-free and modification-free electroanalytical methodology based on anodically pretreated boron-doped diamond electrode is described for the quantification of enrofloxacin. The oxidation of compound was irreversible and presented an adsorption controlled process. The sensitivity of the stripping voltammetric measurements was significantly improved when the anionic surfactant, sodium dodecylsulfate (SDS) was present in the electrolyte solution. Using square-wave stripping mode, a linear response was obtained for enrofloxacin determination in 0.1 mol L-1 HNO3 solution containing 9 x 10(-4) mol L-1 SDS at +1.27 V (vs. Ag/AgCl) (after 60 s accumulation at open-circuit condition). Linearity was found within 0.025 to 1.0 mu g mL(-1) (6.96 x 10(-8)-2.78 x 10(-6) mol L-1) with a detection limit 0.0057 mu g mL(-1) (1.59 x 10(-8) mol L-1). The proposed method could be used for the determination of enrofloxacin in pharmaceutical formulations and the spiked human urine samples with acceptable recoveries.
Description
Senturk, Zuhre/0000-0002-0356-9345; Yardim, Yavuz/0000-0002-9587-096X
Keywords
Enrofloxacin, Anodically Pretreated Boron-Doped Diamond, Square-Wave Adsorptive Stripping Voltammetry, Sodium Dodecyl Sulfate, Pharmaceutical Formulation, Urine Samples
Turkish CoHE Thesis Center URL
WoS Q
Q2
Scopus Q
Q2
Source
Volume
84
Issue
Start Page
95
End Page
102