Voltammetric Method for the Simultaneous Determination of Melatonin and Pyridoxine in Dietary Supplements Using a Cathodically Pretreated Boron-Doped Diamond Electrode
dc.authorid | Yardim, Yavuz/0000-0002-9587-096X | |
dc.authorid | Talay Pinar, Pinar/0000-0003-1027-1456 | |
dc.authorid | Senturk, Zuhre/0000-0002-0356-9345 | |
dc.authorscopusid | 57193907843 | |
dc.authorscopusid | 55807475500 | |
dc.authorscopusid | 55511747958 | |
dc.authorscopusid | 7004177719 | |
dc.authorwosid | Talay Pınar, Pınar/Jfj-2292-2023 | |
dc.authorwosid | Senturk, Zuhre/Aas-5179-2020 | |
dc.contributor.author | Alpar, Nurcan | |
dc.contributor.author | Pinar, Pinar Talay | |
dc.contributor.author | Yardim, Yavuz | |
dc.contributor.author | Senturk, Zuehre | |
dc.date.accessioned | 2025-05-10T17:28:29Z | |
dc.date.available | 2025-05-10T17:28:29Z | |
dc.date.issued | 2017 | |
dc.department | T.C. Van Yüzüncü Yıl Üniversitesi | en_US |
dc.department-temp | [Alpar, Nurcan; Pinar, Pinar Talay; Yardim, Yavuz] Yuzuncu Yil Univ, Dept Analyt Chem, Fac Pharm, TR-65080 Van, Turkey; [Senturk, Zuehre] Yuzuncu Yil Univ, Dept Analyt Chem, Fac Sci, TR-65080 Van, Turkey | en_US |
dc.description | Yardim, Yavuz/0000-0002-9587-096X; Talay Pinar, Pinar/0000-0003-1027-1456; Senturk, Zuhre/0000-0002-0356-9345 | en_US |
dc.description.abstract | The simultaneous voltammetric determination of melatonin (MT) and pyridoxine (PY) has been carried out at a cathodically pretreated boron-doped diamond electrode. By using cyclic voltammetry, a separation of the oxidation peak potentials of both compounds present in mixture was about 0.47 V in Britton-Robinson buffer, pH 2. The results obtained by square-wave voltammetry allowed a method to be developed for determination of MT and PY simultaneously in the ranges 1-100 mu g mL(-1) (4.3x10(-6)-4.3x10(-4) mol L-1) and 10-175 mu g mL(-1) (4.9x10(-5)-8.5x10(-4) mol L-1), with detection limits of 0.14 mu g mL(-1) (6.0x10(-7) mol L-1) and 1.35 mu g mL(-1) (6.6x10(-6) mol L-1), respectively. The proposed method was successfully to the dietary supplements samples containing these compounds for health-caring purposes. | en_US |
dc.description.woscitationindex | Science Citation Index Expanded | |
dc.identifier.doi | 10.1002/elan.201700077 | |
dc.identifier.endpage | 1699 | en_US |
dc.identifier.issn | 1040-0397 | |
dc.identifier.issn | 1521-4109 | |
dc.identifier.issue | 7 | en_US |
dc.identifier.scopus | 2-s2.0-85017425661 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 1691 | en_US |
dc.identifier.uri | https://doi.org/10.1002/elan.201700077 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14720/12057 | |
dc.identifier.volume | 29 | en_US |
dc.identifier.wos | WOS:000405310100005 | |
dc.identifier.wosquality | Q2 | |
dc.language.iso | en | en_US |
dc.publisher | Wiley-v C H verlag Gmbh | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Melatonin | en_US |
dc.subject | Pyridoxine | en_US |
dc.subject | Simultaneous Determination | en_US |
dc.subject | Boron-Doped Diamond Electrode | en_US |
dc.subject | Dietary Supplements | en_US |
dc.title | Voltammetric Method for the Simultaneous Determination of Melatonin and Pyridoxine in Dietary Supplements Using a Cathodically Pretreated Boron-Doped Diamond Electrode | en_US |