Effect of Thermoplastic Mask Hole Diameter on Dose Distribution in the Build-Up Region of Medical Linac
dc.authorid | Demir, Hikmettin/0000-0002-1171-4821 | |
dc.authorid | Gul, Osman Vefa/0000-0002-6773-3132 | |
dc.authorwosid | Demir, Hikmettin/Hga-7385-2022 | |
dc.authorwosid | Gul, Osman Vefa/Aaf-2848-2021 | |
dc.contributor.author | Demir, Hikmettin | |
dc.contributor.author | Gul, Osman Vefa | |
dc.date.accessioned | 2025-05-10T17:23:55Z | |
dc.date.available | 2025-05-10T17:23:55Z | |
dc.date.issued | 2024 | |
dc.department | T.C. Van Yüzüncü Yıl Üniversitesi | en_US |
dc.department-temp | [Demir, Hikmettin] Van Yuzuncu Yil Univ, Fac Med, Dept Radiat Oncol, Van, Turkiye; [Gul, Osman Vefa] Selcuk Univ, Fac Med, Dept Radiat Oncol, Konya, Turkiye | en_US |
dc.description | Demir, Hikmettin/0000-0002-1171-4821; Gul, Osman Vefa/0000-0002-6773-3132 | en_US |
dc.description.abstract | This study aims to investigate the effect of variations in the hole diameter of unstretched thermoplastic masks offered by a single company on the dose distribution in the build-up region. 2, 2.5, 3 and 4 mm hole diameters masks with the same properties were irradiated with 6 MV X-rays and dose distribution was analyzed according to the open field. Dose measurements were obtained with a parallel plane ionization chamber. All irradiations were repeated for 5 x 5, 8 x 8, 10 x 10 and 15 x 15 cm 2 beam fields. It was observed that the mask had a bolus effect in all measurements. It was observed that this bolus effect varied especially depending on the hole diameter in the mask. In a 10 x 10 cm 2 field, the d max depth without mask was 15 mm, while the d max for masks with 2, 2.5, 3 and 4 mm hole diameters was 11, 12, 13 and 13 mm, respectively. It was observed that the mask hole diameter affected the d max depth. Thermoplastic masks with large hole diameters increase the surface dose less than those with small hole diameters. | en_US |
dc.description.woscitationindex | Science Citation Index Expanded | |
dc.identifier.doi | 10.1016/j.jrras.2024.100884 | |
dc.identifier.issn | 1687-8507 | |
dc.identifier.issue | 2 | en_US |
dc.identifier.scopusquality | N/A | |
dc.identifier.uri | https://doi.org/10.1016/j.jrras.2024.100884 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14720/11028 | |
dc.identifier.volume | 17 | en_US |
dc.identifier.wos | WOS:001217209900001 | |
dc.identifier.wosquality | Q3 | |
dc.language.iso | en | en_US |
dc.publisher | Elsevier | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Radiotherapy | en_US |
dc.subject | Thermoplastic Mask | en_US |
dc.subject | Percentage Depth Dose | en_US |
dc.subject | Surface Dose | en_US |
dc.title | Effect of Thermoplastic Mask Hole Diameter on Dose Distribution in the Build-Up Region of Medical Linac | en_US |
dc.type | Article | en_US |