YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Quantification of Ferulic Acid Using Square-Wave Voltammetric Method at an Unmodified Boron-Doped Diamond Electrode

dc.authorscopusid 55807475500
dc.authorscopusid 57220154278
dc.authorscopusid 57218701407
dc.authorscopusid 55511747958
dc.authorwosid Talay Pınar, Pınar/Jfj-2292-2023
dc.authorwosid Ali, Hoshyar/Aay-8463-2021
dc.contributor.author Pinar, Pinar Talay
dc.contributor.author Barzani, Hemn A. H.
dc.contributor.author Ali, Hoshyar Saadi
dc.contributor.author Yardim, Yavuz
dc.date.accessioned 2025-05-10T17:18:22Z
dc.date.available 2025-05-10T17:18:22Z
dc.date.issued 2023
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Pinar, Pinar Talay; Yardim, Yavuz] Van Yuzuncu Yil Univ, Fac Pharm, Dept Analyt Chem, TR-65080 Van, Turkiye; [Barzani, Hemn A. H.] Aynda Private Tech Inst, Dept Pharm, Erbil 44001, Iraq; [Ali, Hoshyar Saadi] Knowledge Univ, Coll Sci, Dept Med Lab Sci, Kirkuk 44001, Erbil, Iraq; [Ali, Hoshyar Saadi] Van Yuzuncu Yil Univ, Fac Sci, Dept Analyt Chem, TR-65080 Van, Turkiye en_US
dc.description.abstract For the first time, a boron-doped diamond electrode was employed in square-wave voltammetry for the sensitive and selective measurement of ferulic acid (FA). The impact of the electrode's pretreatment procedure on the current response was investigated, leading to the discovery that the consecutive pretreatment approach yielded the most optimal signal results. This determination was made upon observing that the highest quality signal could be obtained through this method. The electrochemical oxidation of FA was studied in aqueous media on a cathodically pretreated boron-doped diamond electrode. FA was shown to have two sets of oxidation/reduction peaks when tested in aqueous solutions using cyclic voltammetry. Diffusion governs the electrode process, which is pH-dependent. In 0.1 mol dm-3 H2SO4, the calibration curves were linear for FA peak over dynamic ranges of 5.1 x 10-7-4.1 x 10-5 mol dm-3, via a detection limit of 1.5 x 10-7 mol dm-3. The practical applicability of the developed methodology was tested in the commercial ampoule formulation of FA. The method can be used instead of other analytical methods because it is fast, easy to use, and cheap, has a wide calibration range, and gives consistent results. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1007/s00706-023-03126-8
dc.identifier.endpage 1233 en_US
dc.identifier.issn 0026-9247
dc.identifier.issn 1434-4475
dc.identifier.issue 11 en_US
dc.identifier.scopus 2-s2.0-85172993729
dc.identifier.scopusquality Q2
dc.identifier.startpage 1225 en_US
dc.identifier.uri https://doi.org/10.1007/s00706-023-03126-8
dc.identifier.uri https://hdl.handle.net/20.500.14720/9662
dc.identifier.volume 154 en_US
dc.identifier.wos WOS:001075482400001
dc.identifier.wosquality Q3
dc.language.iso en en_US
dc.publisher Springer Wien en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Ferulic Acid en_US
dc.subject Voltammetry en_US
dc.subject Boron-Doped Diamond Electrode en_US
dc.subject Injection Sample en_US
dc.title Quantification of Ferulic Acid Using Square-Wave Voltammetric Method at an Unmodified Boron-Doped Diamond Electrode en_US
dc.type Article en_US

Files