YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

The Comparison of Diffusion Weighted Imaging (Dwi) With Other Breast Mri Parameters in the Diagnosis of Breast Masses

dc.authorscopusid 54998741200
dc.authorscopusid 55438040300
dc.authorscopusid 23570636600
dc.authorscopusid 56690325400
dc.authorscopusid 56925488100
dc.contributor.author Özgökçe, M.
dc.contributor.author Havan, N.
dc.contributor.author Cuce, F.
dc.contributor.author Durmaz, F.
dc.contributor.author Sakci, Z.
dc.date.accessioned 2025-05-10T17:01:59Z
dc.date.available 2025-05-10T17:01:59Z
dc.date.issued 2019
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp Özgökçe M., Yuzuncu Yil University, Radiology Department, Van, Turkey; Havan N., Kartal Kosuyolu High Specialization Training and Research Hospital, Department of Radiology, Istanbul, 34000, Turkey; Cuce F., Gulhane Training and Research Hospital, Department of Radiology, Ankara, 06000, Turkey; Durmaz F., Yuzuncu Yil University, Radiology Department, Van, Turkey; Sakci Z., Umraniye Training and Research Hospital, Department of Radiology, Istanbul, 34000, Turkey en_US
dc.description.abstract The breast MRI parameters such as morphologic features, enhancement kinetics and diffusion restriction can be used for the differential diagnosis. We aimed to compare the Apperant Diffusion Coefficient (ADC) values of masses with other MRI parameters in diagnosis of breast masses. Between March 2014 and September 2017, 49 female patients in whom a breast mass was diagnosed, determined using ultrasound and mammography and who were further examined with MRI, were enrolled to this study. Total 51 lesions were detected. Routine breast MRI protocol was performed and images were evaluated. The ADC cut-off value was taken as 1,1×10-3mm2 /s according to the literature. Fifty-one lesions were diagnosed with biopsy. Of these lesions, 23 (45.1%) were malignant (20 invasive ductal carcinoma and others) and 28 (54.9%) were benign (20 fibroadenomas and others). The accuracy rate of DCE assessment of MRI was 90,9% for benign lesions in with a type 1 curved lesions, and 81,8% for malign lesions in with a type 3 curved lesions. The accuracy rate of ADC values was 93,1% for benign lesions and 95,5% for malign lesions. We believe that the ADC value can provide a higher diagnostic accuracy with the combination of morphological characteristics and contrast kinetics of the lesion and that ADC can be used alone because of its high diagnostic accuracy in some cases. © 2019, Yuzuncu Yil Universitesi Tip Fakultesi. All rights reserved. en_US
dc.identifier.doi 10.5505/ejm.2019.60590
dc.identifier.endpage 275 en_US
dc.identifier.issn 1301-0883
dc.identifier.issue 3 en_US
dc.identifier.scopus 2-s2.0-85071265240
dc.identifier.scopusquality Q4
dc.identifier.startpage 271 en_US
dc.identifier.trdizinid 326593
dc.identifier.uri https://doi.org/10.5505/ejm.2019.60590
dc.identifier.uri https://hdl.handle.net/20.500.14720/5367
dc.identifier.volume 24 en_US
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher Yuzuncu Yil Universitesi Tip Fakultesi en_US
dc.relation.ispartof Eastern Journal of Medicine en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Adc en_US
dc.subject Breast Masses en_US
dc.subject Breast Mri en_US
dc.title The Comparison of Diffusion Weighted Imaging (Dwi) With Other Breast Mri Parameters in the Diagnosis of Breast Masses en_US
dc.type Article en_US

Files