Electroanalytical Determination of Salbutamol in Pharmaceutical Formulations Using Cathodically Pretreated Boron-Doped Diamond Electrode
dc.authorid | Ali, Hoshyar/0000-0002-9138-485X | |
dc.authorid | Senturk, Zuhre/0000-0002-0356-9345 | |
dc.authorid | Yardim, Yavuz/0000-0002-9587-096X | |
dc.authorscopusid | 55807475500 | |
dc.authorscopusid | 57218701407 | |
dc.authorscopusid | 57193918077 | |
dc.authorscopusid | 55511747958 | |
dc.authorscopusid | 7004177719 | |
dc.authorwosid | Talay Pınar, Pınar/Jfj-2292-2023 | |
dc.authorwosid | Ali, Hoshyar/Aay-8463-2021 | |
dc.authorwosid | Senturk, Zuhre/Aas-5179-2020 | |
dc.contributor.author | Talay Pinar, Pinar | |
dc.contributor.author | Ali, Hoshyar Saadi | |
dc.contributor.author | Abdullah, Abdullah Abdulwahed | |
dc.contributor.author | Yardim, Yavuz | |
dc.contributor.author | Senturk, Zuhre | |
dc.date.accessioned | 2025-05-10T17:58:03Z | |
dc.date.available | 2025-05-10T17:58:03Z | |
dc.date.issued | 2018 | |
dc.department | T.C. Van Yüzüncü Yıl Üniversitesi | en_US |
dc.department-temp | [Talay Pinar, Pinar; Yardim, Yavuz] Van Yuzuncu Yil Univ, Fac Pharm, Dept Analyt Chem, TR-65080 Van, Turkey; [Ali, Hoshyar Saadi; Abdullah, Abdullah Abdulwahed; Senturk, Zuhre] Van Yuzuncu Yil Univ, Fac Sci, Dept Analyt Chem, TR-65080 Van, Turkey | en_US |
dc.description | Ali, Hoshyar/0000-0002-9138-485X; Senturk, Zuhre/0000-0002-0356-9345; Yardim, Yavuz/0000-0002-9587-096X | en_US |
dc.description.abstract | This paper examined for the first time the possibilities of the usage of the cathodically pretreated borondoped diamond (CPT-BDD) electrode for the redox behavior of salbutamol (SAL) using cyclic and adsorptive stripping voltammetry. The cyclic voltammograms showed an irreversible and adsorption-controlled oxidation peak at about +1.0 V in the Britton-Robinson (BR) buffer (pH 9.0) solution. Under the optimized experimental condition, using square-wave adsorptive stripping mode, the compound yielded a well-defined voltammetric response in BR buffer, pH 9.0 at +0.95 V (vs. Ag/AgCl) (after 30 s accumulation at an open circuit condition). A linear calibration graph was obtained in the concentration range of 4.15 to 83 mu g mL(-1) (1.73x10(-5) -3.47x10(-4) M). A detection limit of 1.21 mu g mL(-1) (5.06x10(-6) M) was observed. The suggested method was also applied to the determination of SAL in the drug formulations. | en_US |
dc.description.woscitationindex | Emerging Sources Citation Index | |
dc.identifier.doi | 10.12991/jrp.2018.88 | |
dc.identifier.endpage | 468 | en_US |
dc.identifier.issn | 2630-6344 | |
dc.identifier.issn | 1309-0801 | |
dc.identifier.issue | 3 | en_US |
dc.identifier.scopus | 2-s2.0-85056599771 | |
dc.identifier.scopusquality | Q4 | |
dc.identifier.startpage | 460 | en_US |
dc.identifier.trdizinid | 370953 | |
dc.identifier.uri | https://doi.org/10.12991/jrp.2018.88 | |
dc.identifier.uri | https://search.trdizin.gov.tr/en/yayin/detay/370953/electroanalytical-determination-of-salbutamol-in-pharmaceutical-formulations-using-cathodicallypretreated-boron-doped-diamond-electrode | |
dc.identifier.uri | https://hdl.handle.net/20.500.14720/20252 | |
dc.identifier.volume | 22 | en_US |
dc.identifier.wos | WOS:000445922100015 | |
dc.identifier.wosquality | N/A | |
dc.language.iso | en | en_US |
dc.publisher | Marmara Univ | en_US |
dc.relation.ispartof | Marmara Pharmaceutical Journal | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Salbutamol | en_US |
dc.subject | Boron-Doped Diamond Electrode | en_US |
dc.subject | Square-Wave Adsorptive Stripping Voltammetry | en_US |
dc.subject | Pharmaceutical Formulations | en_US |
dc.title | Electroanalytical Determination of Salbutamol in Pharmaceutical Formulations Using Cathodically Pretreated Boron-Doped Diamond Electrode | en_US |
dc.type | Article | en_US |