YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

The Effect of Heat-Treated Single-File Systems on Dentinal Crack Formation

dc.authorscopusid 57204283260
dc.authorscopusid 57222154886
dc.contributor.author Ozlek, E.
dc.contributor.author Gunduz, H.
dc.date.accessioned 2025-05-10T17:02:37Z
dc.date.available 2025-05-10T17:02:37Z
dc.date.issued 2021
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp Ozlek E., Department of Endodontics, Faculty of Dentistry, The University of Van Yuzuncu Yil, Van, Turkey; Gunduz H., Department of Endodontics, Faculty of Dentistry, The University of Van Yuzuncu Yil, Van, Turkey en_US
dc.description.abstract Objectives: The aim of this study was to compare the formation of dentinal crack after root canal preparation performed with different heat treated single-file systems. Materials and Methods: Forty mandibular premolar teeth were randomly divided into four groups according to the file system to be used during the preparation (n = 10): Group 1: Reciproc Blue; group 2: One Curve; group 3: HyFlex EDM; group 4: (control group) hand files. During the cleaning and shaping, irrigation was performed with a total of 10 ml of 5.25% sodium hypochlorite and 2 mL of distilled water. Then sections were taken from the roots (3, 6 and 9 mm). Sections were examined on a stereomicroscope to determine the presence of cracks. Chi-square test was used for data analysis. Results: There was a significant difference between the groups in dentinal crack frequency (P <.05). HyFlex EDM (13.3%) caused less dentinal crack than One Curve (26.7%) and Reciproc Blue (30%). No cracks were observed in the control group. When 3, 6, and 9 mm were evaluated within themselves, dentinal crack formation did not differ according to the groups (P > 0.05). A statistically higher mean value was obtained in the control group compared to the other groups in terms of working time (P < 0.001). Conclusions: All the files used during root canal preparation formed dentin crack. Hy-Flex EDM caused less dentinal cracks than other file systems. The flexibility of nickel-titanium instruments because of heat treatment seems to have a significant influence on dentinal crack formation. © 2021 Wolters Kluwer Medknow Publications. All rights reserved. en_US
dc.identifier.doi 10.4103/njcp.njcp_250_20
dc.identifier.endpage 424 en_US
dc.identifier.issn 1119-3077
dc.identifier.issue 3 en_US
dc.identifier.pmid 33723118
dc.identifier.scopus 2-s2.0-85102912375
dc.identifier.scopusquality Q2
dc.identifier.startpage 418 en_US
dc.identifier.uri https://doi.org/10.4103/njcp.njcp_250_20
dc.identifier.uri https://hdl.handle.net/20.500.14720/5600
dc.identifier.volume 24 en_US
dc.identifier.wosquality Q4
dc.language.iso en en_US
dc.publisher Wolters Kluwer Medknow Publications en_US
dc.relation.ispartof Nigerian Journal of Clinical Practice en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Dentinal Crack en_US
dc.subject Hyflex Edm en_US
dc.subject One Curve en_US
dc.subject Reciproc Blue en_US
dc.subject Single-File Systems en_US
dc.title The Effect of Heat-Treated Single-File Systems on Dentinal Crack Formation en_US
dc.type Article en_US

Files