YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Dsogi-Pll Based Power Control Method To Mitigate Control Errors Under Disturbances of Grid Connected Hybrid Renewable Power Systems

dc.authorid Meral, Mehmet Emin/0000-0003-0841-4630
dc.authorscopusid 24921917000
dc.authorscopusid 57194050701
dc.authorwosid Çeli̇k, Doğan/Aal-8311-2020
dc.contributor.author Meral, Mehmet Emin
dc.contributor.author Celik, Dogan
dc.date.accessioned 2025-05-10T17:04:52Z
dc.date.available 2025-05-10T17:04:52Z
dc.date.issued 2018
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Meral, Mehmet Emin; Celik, Dogan] Van Yuzuncu Yil Univ, Dept Elect & Elect Engn, TR-65090 Tusba Van, Turkey en_US
dc.description Meral, Mehmet Emin/0000-0003-0841-4630 en_US
dc.description.abstract The control of power converter devices is one of the main research lines in interfaced renewable energy sources, such as solar cells and wind turbines. Therefore, suitable control algorithms should be designed in order to regulate power or current properly and attain a good power quality for some disturbances, such as voltage sag/swell, voltage unbalances and fluctuations, long interruptions, and harmonics. Various synchronisation techniques based control strategies are implemented for the hybrid power system applications under unbalanced conditions in literature studies. In this paper, synchronisation algorithms based Proportional-Resonant (PR) power/current controller is applied to the hybrid power system (solar cell + wind turbine + grid), and Dual Second Order Generalized Integrator-Phase Locked Loop (DSOGI-PLL) based PR controller in stationary reference frame provides a solution to overcome these problems. The influence of various cases, such as unbalance, and harmonic conditions, is examined, analysed and compared to the PR controllers based on DSOGI-PLL and SRF-PLL. The results verify the effectiveness and correctness of the proposed DSOGI-PLL based power control method. en_US
dc.description.woscitationindex Emerging Sources Citation Index
dc.identifier.doi 10.15598/aeee.v16i1.2485
dc.identifier.endpage 91 en_US
dc.identifier.issn 1336-1376
dc.identifier.issn 1804-3119
dc.identifier.issue 1 en_US
dc.identifier.scopus 2-s2.0-85044971796
dc.identifier.scopusquality Q3
dc.identifier.startpage 81 en_US
dc.identifier.uri https://doi.org/10.15598/aeee.v16i1.2485
dc.identifier.uri https://hdl.handle.net/20.500.14720/6140
dc.identifier.volume 16 en_US
dc.identifier.wos WOS:000429160100008
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher Vsb-technical Univ Ostrava en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Dsogi en_US
dc.subject Grid Disturbances en_US
dc.subject Power Quality en_US
dc.subject Pr Controller en_US
dc.subject Renewable Energy Sources en_US
dc.title Dsogi-Pll Based Power Control Method To Mitigate Control Errors Under Disturbances of Grid Connected Hybrid Renewable Power Systems en_US
dc.type Article en_US

Files