YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Comparison of Anterior Chamber Depth Measurements Taken With the Pentacam, Orbscan Iiz and Iolmaster in Myopic and Emmetropic Eyes

dc.authorwosid Utine, Canan/Abb-4429-2020
dc.contributor.author Utine, Canan Asli
dc.contributor.author Altin, Feyza
dc.contributor.author Cakir, Hanefi
dc.contributor.author Perente, Irfan
dc.date.accessioned 2025-05-10T17:19:41Z
dc.date.available 2025-05-10T17:19:41Z
dc.date.issued 2009
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Altin, Feyza] SB Okmeydani Res & Training Hosp, Dept Ophthalmol, Istanbul, Turkey; [Cakir, Hanefi] Turkiye Hosp Eye Clin, Dept Ophthalmol, Istanbul, Turkey; [Perente, Irfan] Beyoglu Eye Res & Training Hosp, Dept Ophthalmol, Istanbul, Turkey; [Utine, Canan Asli] Yeditepe Univ, Hosp Eye, Turkiye Hosp Eye Clin, Dept Ophthalmol, Istanbul, Turkey en_US
dc.description.abstract This study determined to assess the degree of agreement between anterior chamber depth (ACD) measurements obtained using three different devices and to analyse the relationship between ACD and spherical equivalent (SE) refraction. In this cross-sectional study, 42 eyes of 42 patients with a mean SE of - 4.69 +/- 4.61 D (range 0.00 D to - 14.88 D) were analysed. Measurements of ACD between the corneal epithelium and the anterior surface of the crystalline lens, obtained using the Pentacam, Orbscan IIz and IOLMaster, were compared. The relationships between SE and ACD measurements obtained with different devices were also investigated. The results were analysed using Bland-Altman analyses, single-sample t-test and Pearson's correlation test. Orbscan ACD measurements were an average of 0.05 mm less than Pentacam measurements (p = 0.01). IOLMaster measurements were an average of 0.06 mm less than Orbscan measurements (p < 0.001). None of the ACD values measured by any of the devices were correlated with increasing SE (p > 0.05 for all). There was a weak positive correlation between SE and the difference in ACD measurements with Pentacam and Orbscan (p = 0.04); however, the differences between Pentacam and IOLMaster ACD measurements and Orbscan and IOLMaster ACD measurements seemed to be independent of SE (p = 0.17 and p = 0.54, respectively). The ACD in clinically normal eyes is measured differently by various non-ultrasonic devices. However, the observed mean error between these modalities is too small to create any noticeable difference in refractive outcome. No significant relationship was found between SE and ACD measurements obtained by Pentacam, Orbscan or IOLMaster. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1111/j.1755-3768.2008.01278.x
dc.identifier.endpage 391 en_US
dc.identifier.issn 1755-375X
dc.identifier.issn 1755-3768
dc.identifier.issue 4 en_US
dc.identifier.pmid 18778337
dc.identifier.scopusquality Q1
dc.identifier.startpage 386 en_US
dc.identifier.uri https://doi.org/10.1111/j.1755-3768.2008.01278.x
dc.identifier.uri https://hdl.handle.net/20.500.14720/9882
dc.identifier.volume 87 en_US
dc.identifier.wos WOS:000266420700005
dc.identifier.wosquality Q2
dc.language.iso en en_US
dc.publisher Wiley en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Anterior Chamber Depth en_US
dc.subject Iolmaster en_US
dc.subject Orbscan en_US
dc.subject Pentacam en_US
dc.title Comparison of Anterior Chamber Depth Measurements Taken With the Pentacam, Orbscan Iiz and Iolmaster in Myopic and Emmetropic Eyes en_US
dc.type Article en_US