YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Pvc-Membrane Potentiometric Sensor for the Determination of Tamoxifen in Pharmaceutical Formulations

dc.authorid Topcu, Cihan/0000-0002-1600-5741
dc.authorid Cubuk, Osman/0000-0001-7858-2803
dc.authorid Coldur, Fatih/0000-0002-7037-2825
dc.authorscopusid 56841645900
dc.authorscopusid 25921912000
dc.authorscopusid 37036337700
dc.authorscopusid 15721741100
dc.authorwosid Cubuk, Osman/Lsl-7666-2024
dc.authorwosid Çoldur, Fati̇h/Cah-5824-2022
dc.contributor.author Kanberoglu, Gulsah Saydan
dc.contributor.author Coldur, Fatih
dc.contributor.author Topcu, Cihan
dc.contributor.author Cubuk, Osman
dc.date.accessioned 2025-05-10T17:39:55Z
dc.date.available 2025-05-10T17:39:55Z
dc.date.issued 2015
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Kanberoglu, Gulsah Saydan] Yuzuncu Yil Univ, Dept Chem, Fac Sci, TR-65080 Van, Turkey; [Coldur, Fatih; Topcu, Cihan; Cubuk, Osman] Erzincan Univ, Fac Arts & Sci, Dept Chem, TR-24100 Erzincan, Turkey en_US
dc.description Topcu, Cihan/0000-0002-1600-5741; Cubuk, Osman/0000-0001-7858-2803; Coldur, Fatih/0000-0002-7037-2825 en_US
dc.description.abstract Novel tamoxifen-selective potentiometric electrodes based on various ion associations of tamoxifen were developed. The most suitable membrane composition, which has the best potentiometric characteristics, was examined under steady-state conditions. The membrane composed of (w/w) 3% tamoxifen-phosphomolibdate ion pair, 32% poly(vinylchloride), and 65% 2-nitrophenyloctylether was determined as the membrane with the best analytical properties. On the condition of pH = 2-6, the fabricated electrode exhibited linear responses over the concentration range of 9.1 x 10(-6) -1 x 10(-3) M tamoxifen solutions (R-2 = 0.9989) with a sensitivity of 42.9 +/- 0.3 mV/decade, detection limit of 7.3 +/- 0.4 x 10(-6) M and short response time of approximate to 25 s. The influences of some alkaline, alkaline earth metals, biologically significant molecules, and some pharmaceutical species over electrode responses were studied. The proposed electrode was applied for the determination of tamoxifen contents of some pharmaceutical formulations by using standard addition method. The potentiometric analysis results obtained for the pharmaceutical formulations were in good harmony with the results obtained by high performance liquid chromatography at 95% confidence level. en_US
dc.description.sponsorship Yuzuncu Yil University Research Foundation [2013-FEN-B044] en_US
dc.description.sponsorship This work was supported by Yuzuncu Yil University Research Foundation under Grant 2013-FEN-B044. The associate editor coordinating the review of this paper and approving it for publication was Dr. Pantelis Georgiou. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1109/JSEN.2015.2454053
dc.identifier.endpage 6207 en_US
dc.identifier.issn 1530-437X
dc.identifier.issn 1558-1748
dc.identifier.issue 11 en_US
dc.identifier.scopus 2-s2.0-84941595446
dc.identifier.scopusquality Q1
dc.identifier.startpage 6199 en_US
dc.identifier.uri https://doi.org/10.1109/JSEN.2015.2454053
dc.identifier.uri https://hdl.handle.net/20.500.14720/15034
dc.identifier.volume 15 en_US
dc.identifier.wos WOS:000360450900018
dc.identifier.wosquality Q1
dc.language.iso en en_US
dc.publisher Ieee-inst Electrical Electronics Engineers inc en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Drug Analysis en_US
dc.subject Ion-Selective Electrode en_US
dc.subject Potentiometry en_US
dc.subject Tamoxifen Determination en_US
dc.title Pvc-Membrane Potentiometric Sensor for the Determination of Tamoxifen in Pharmaceutical Formulations en_US
dc.type Article en_US