YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Simple and Rapid Voltammetric Determination of Cephalosporin Drug Cefixime on Boron-Doped Diamond Electrode

dc.authorid Keskin, Ertugrul/0000-0001-5216-3520
dc.authorid Yardim, Yavuz/0000-0002-9587-096X
dc.authorscopusid 35740840400
dc.authorscopusid 57210193426
dc.authorscopusid 57211602750
dc.authorscopusid 55511747958
dc.authorwosid Keskin, Ertuğrul/Ael-9615-2022
dc.contributor.author Keskin, Ertugrul
dc.contributor.author Allahverdiyeva, Shabnam
dc.contributor.author Seker, Hamza
dc.contributor.author Yardim, Yavuz
dc.date.accessioned 2025-05-10T17:26:00Z
dc.date.available 2025-05-10T17:26:00Z
dc.date.issued 2019
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Keskin, Ertugrul] Adiyaman Univ, Dept Analyt Chem, Fac Pharm, TR-02040 Adiyaman, Turkey; [Allahverdiyeva, Shabnam] Van Yuzuncu Yil Univ, Dept Biochem, Fac Sci, TR-65080 Van, Turkey; [Seker, Hamza; Yardim, Yavuz] Van Yuzuncu Yil Univ, Dept Analyt Chem, Fac Pharm, TR-65080 Van, Turkey en_US
dc.description Keskin, Ertugrul/0000-0001-5216-3520; Yardim, Yavuz/0000-0002-9587-096X en_US
dc.description.abstract A boron-doped diamond electrode was used for the first time in sensitive and selective analysis of cefixime, a third-generation cephalosporin drug, using the square-wave voltammetry technique. The effect of the pretreatment procedure on the current response at the electrode was investigated. The best signals were obtained by polishing the electrode with a polishing pad after applying anodic and cathodic electrochemical pretreatment to the electrode. Cefixime gave a well-defined, irreversible and diffusion-controlled oxidation peak in 0.1 mol dm(-3) H2SO4 support electrolyte at + 1.25 V (vs. Ag/AgCl 3 mol dm(-3) NaCl). Under the best instrumental conditions and with the pretreatment procedure, a calibration curve was obtained with linearity between 2.2x10(-6) mol dm(-3) and 1.3x10(-4) mol dm(-3) at 5.9x10(-7) mol dm(-3) detection limit. The effect of possible interference substances on the current response for cefixime was investigated and the method was found to have sufficient selectivity. The developed method was successfully applied for the analysis of cefixime from pharmaceutical formulations. The method can be an alternative to the other analytical approaches due to its speed, simplicity, low cost, wide calibration range, and repeatable responses. [GRAPHICS] . en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1007/s00706-019-02508-1
dc.identifier.endpage 1902 en_US
dc.identifier.issn 0026-9247
dc.identifier.issn 1434-4475
dc.identifier.issue 11 en_US
dc.identifier.scopus 2-s2.0-85074562478
dc.identifier.scopusquality Q2
dc.identifier.startpage 1895 en_US
dc.identifier.uri https://doi.org/10.1007/s00706-019-02508-1
dc.identifier.uri https://hdl.handle.net/20.500.14720/11527
dc.identifier.volume 150 en_US
dc.identifier.wos WOS:000494183000002
dc.identifier.wosquality Q3
dc.language.iso en en_US
dc.publisher Springer Wien en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Cefixime en_US
dc.subject Square-Wave Voltammetry en_US
dc.subject Boron-Doped Diamond Electrode en_US
dc.subject Pretreatment Procedures en_US
dc.subject Pharmaceutical Formulation en_US
dc.title Simple and Rapid Voltammetric Determination of Cephalosporin Drug Cefixime on Boron-Doped Diamond Electrode en_US
dc.type Article en_US

Files