Comparative of Mil101(Cr) and Nano-Mil101(cr) Electrode as an Electrochemical Hydrogen Peroxide Sensor
dc.authorscopusid | 57199289420 | |
dc.authorscopusid | 57189211902 | |
dc.authorscopusid | 8226754300 | |
dc.authorwosid | Gülcan, Mehmet/Aat-1504-2021 | |
dc.contributor.author | Salman, Firat | |
dc.contributor.author | Kazici, Hilal Celik | |
dc.contributor.author | Gulcan, Mehmet | |
dc.date.accessioned | 2025-05-10T17:36:42Z | |
dc.date.available | 2025-05-10T17:36:42Z | |
dc.date.issued | 2022 | |
dc.department | T.C. Van Yüzüncü Yıl Üniversitesi | en_US |
dc.department-temp | [Salman, Firat; Kazici, Hilal Celik; Gulcan, Mehmet] Van Yuzuncu Yil Univ, Sci Fac, Dept Chem, TR-65080 Van, Turkey | en_US |
dc.description.abstract | Herein, an electrochemical sensor for the detection of H2O2 based on nafion glassy carbon electrode modified with MIL101(Cr) and nano-MIL101(Cr) are developed and its electrochemical characterizations analyzed by CV and CA. In comparison with the NGCE, MIL101/NGCE and nano-MIL101/NGCE, the nano-MIL101/NGCE showed a sharp redox peak specific to H2O2 was obtained in the phosphate-calibrated solution. nano-MIL101/NGCE exhibited good linear response in terms of the relationship between peak currents and concentrations as from 0 to 650 mu M (R-2=0.99), with a low limit of detection 3.8 mu M, high sensitivity 986 mu A mM(-1) cm(-2) and nano-MIL101/NGCE exhibited ideal repeatability, reproducibility, stability and the interference-free perception of H2O2. | en_US |
dc.description.woscitationindex | Science Citation Index Expanded | |
dc.identifier.doi | 10.1002/elan.202200005 | |
dc.identifier.endpage | 1609 | en_US |
dc.identifier.issn | 1040-0397 | |
dc.identifier.issn | 1521-4109 | |
dc.identifier.issue | 10 | en_US |
dc.identifier.scopus | 2-s2.0-85128011946 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 1598 | en_US |
dc.identifier.uri | https://doi.org/10.1002/elan.202200005 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14720/14158 | |
dc.identifier.volume | 34 | en_US |
dc.identifier.wos | WOS:000781615700001 | |
dc.identifier.wosquality | Q2 | |
dc.language.iso | en | en_US |
dc.publisher | Wiley-v C H verlag Gmbh | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Electrocatalysis | en_US |
dc.subject | Hydrogen Peroxide | en_US |
dc.subject | Metal-Organic Framework | en_US |
dc.subject | Mil101(Cr) | en_US |
dc.subject | Nafion Glassy Carbon Electrode | en_US |
dc.title | Comparative of Mil101(Cr) and Nano-Mil101(cr) Electrode as an Electrochemical Hydrogen Peroxide Sensor | en_US |
dc.type | Article | en_US |