The Effects of Corneal Edema on the Intraocular Pressure Measurements
dc.authorscopusid | 57188826172 | |
dc.authorscopusid | 57195679419 | |
dc.authorscopusid | 36865943600 | |
dc.authorscopusid | 57216490881 | |
dc.authorscopusid | 6701592325 | |
dc.contributor.author | Seven, E. | |
dc.contributor.author | Tekin, S. | |
dc.contributor.author | Batur, M. | |
dc.contributor.author | Yavuzer, B. | |
dc.contributor.author | Yaşar, T. | |
dc.date.accessioned | 2025-05-10T17:02:13Z | |
dc.date.available | 2025-05-10T17:02:13Z | |
dc.date.issued | 2020 | |
dc.department | T.C. Van Yüzüncü Yıl Üniversitesi | en_US |
dc.department-temp | Seven E., Department of Ophthalmology, Van Yüzüncü Yıl University, Van, Turkey; Tekin S., Department of Ophthalmology, Van Yüzüncü Yıl University, Van, Turkey; Batur M., Department of Ophthalmology, Van Yüzüncü Yıl University, Van, Turkey; Yavuzer B., Department of Ophthalmology, Van Yüzüncü Yıl University, Van, Turkey; Yaşar T., Health Sciences University, Beyoglu Eye Training and Research Hospital, İstanbul, Turkey | en_US |
dc.description.abstract | We aimed to evaluate the possible effects of corneal edema on intraocular pressure (IOP) measurements obtained with three different tonometers on the first day after cataract surgery. Sixty-four eyes of the 64 patients underwent phacoemulsification and IOP measurements using Goldmann applanation tonometer (GAT), Tono-Pen applanation tonometer (TAT), and Pascal digital contour tonometer (DCT) the first day after surgery. Central corneal thickness (CCT) measurements were used to quantify the postoperative corneal edema. Intraclass correlation coefficient and Bland-Altman plot were used to assess the compatibility of IOP measurements among three method pairs. TAT and DCT IOP measurements were found to be compatible with each other (p=0.141) in the corneal edema group. The GAT and TAT IOP measurements in the eyes with corneal edema were inversely proportional to the CCT values (p=0.011 and p=0.033, respectively), but the DCT relationship was not statistically significant (p=0.44). The lack of a significant relationship between DCT and CCT in edematous corneas may suggest that DCT, as in normal corneas, can perform CCT-independent measurements. However, there is still no gold standard method for IOP measurement in edematous corneas. © 2020, Yuzuncu Yil Universitesi Tip Fakultesi. All rights reserved. | en_US |
dc.identifier.doi | 10.5505/ejm.2020.16023 | |
dc.identifier.endpage | 292 | en_US |
dc.identifier.issn | 1301-0883 | |
dc.identifier.issue | 2 | en_US |
dc.identifier.scopus | 2-s2.0-85083637134 | |
dc.identifier.scopusquality | Q4 | |
dc.identifier.startpage | 285 | en_US |
dc.identifier.trdizinid | 363721 | |
dc.identifier.uri | https://doi.org/10.5505/ejm.2020.16023 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14720/5450 | |
dc.identifier.volume | 25 | en_US |
dc.identifier.wosquality | N/A | |
dc.language.iso | en | en_US |
dc.publisher | Yuzuncu Yil Universitesi Tip Fakultesi | en_US |
dc.relation.ispartof | Eastern Journal of Medicine | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Corneal Edema | en_US |
dc.subject | Digital Contour Tonometer | en_US |
dc.subject | Goldmann Applanation Tonometer | en_US |
dc.subject | Intraocular Pressure | en_US |
dc.subject | Tono-Pen | en_US |
dc.title | The Effects of Corneal Edema on the Intraocular Pressure Measurements | en_US |
dc.type | Article | en_US |