The Effects of Corneal Edema on the Intraocular Pressure Measurements

dc.authorscopusid 57188826172
dc.authorscopusid 57195679419
dc.authorscopusid 36865943600
dc.authorscopusid 57216490881
dc.authorscopusid 6701592325
dc.contributor.author Seven, E.
dc.contributor.author Tekin, S.
dc.contributor.author Batur, M.
dc.contributor.author Yavuzer, B.
dc.contributor.author Yaşar, T.
dc.date.accessioned 2025-05-10T17:02:13Z
dc.date.available 2025-05-10T17:02:13Z
dc.date.issued 2020
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp Seven E., Department of Ophthalmology, Van Yüzüncü Yıl University, Van, Turkey; Tekin S., Department of Ophthalmology, Van Yüzüncü Yıl University, Van, Turkey; Batur M., Department of Ophthalmology, Van Yüzüncü Yıl University, Van, Turkey; Yavuzer B., Department of Ophthalmology, Van Yüzüncü Yıl University, Van, Turkey; Yaşar T., Health Sciences University, Beyoglu Eye Training and Research Hospital, İstanbul, Turkey en_US
dc.description.abstract We aimed to evaluate the possible effects of corneal edema on intraocular pressure (IOP) measurements obtained with three different tonometers on the first day after cataract surgery. Sixty-four eyes of the 64 patients underwent phacoemulsification and IOP measurements using Goldmann applanation tonometer (GAT), Tono-Pen applanation tonometer (TAT), and Pascal digital contour tonometer (DCT) the first day after surgery. Central corneal thickness (CCT) measurements were used to quantify the postoperative corneal edema. Intraclass correlation coefficient and Bland-Altman plot were used to assess the compatibility of IOP measurements among three method pairs. TAT and DCT IOP measurements were found to be compatible with each other (p=0.141) in the corneal edema group. The GAT and TAT IOP measurements in the eyes with corneal edema were inversely proportional to the CCT values (p=0.011 and p=0.033, respectively), but the DCT relationship was not statistically significant (p=0.44). The lack of a significant relationship between DCT and CCT in edematous corneas may suggest that DCT, as in normal corneas, can perform CCT-independent measurements. However, there is still no gold standard method for IOP measurement in edematous corneas. © 2020, Yuzuncu Yil Universitesi Tip Fakultesi. All rights reserved. en_US
dc.identifier.doi 10.5505/ejm.2020.16023
dc.identifier.endpage 292 en_US
dc.identifier.issn 1301-0883
dc.identifier.issue 2 en_US
dc.identifier.scopus 2-s2.0-85083637134
dc.identifier.scopusquality Q4
dc.identifier.startpage 285 en_US
dc.identifier.trdizinid 363721
dc.identifier.uri https://doi.org/10.5505/ejm.2020.16023
dc.identifier.uri https://hdl.handle.net/20.500.14720/5450
dc.identifier.volume 25 en_US
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher Yuzuncu Yil Universitesi Tip Fakultesi en_US
dc.relation.ispartof Eastern Journal of Medicine en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Corneal Edema en_US
dc.subject Digital Contour Tonometer en_US
dc.subject Goldmann Applanation Tonometer en_US
dc.subject Intraocular Pressure en_US
dc.subject Tono-Pen en_US
dc.title The Effects of Corneal Edema on the Intraocular Pressure Measurements en_US
dc.type Article en_US