Investigation of Shielding Parameters of Fast Neutrons for Some Chemotherapy Drugs by Different Calculation Methods
No Thumbnail Available
Date
2023
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Prof.Dr. İskender AKKURT
Abstract
In this study, we investigated the neutron attenuation properties of twelve different chemotherapy drugs utilizing various computational techniques. The computed fast neutron effective removal cross-section (ΣR, cm-1) results were compared with empirical formulas, Monte Carlo simulation data obtained from MCNP, MRCsC, and Phy-X/PSD computer program results. Additionally, within each calculation method, the half-value layer (HVL) and the mean free path (λ) values were determined. Our calculations revealed that, when compared to water and paraffin, Gemcitabine, Etoposide, Vincristine, and Doxorubicin exhibited the highest ΣR values, while Oxaliplatin exhibited the lowest ΣR value. Understanding and determining the radiation properties of drugs, especially in treatment methods involving radiation, will provide an advantage for both patients and clinical personnel. t © IJCESEN.
Description
Keywords
Chemotherapy Drugs, Mrcsc, Neutron Shielding, Phy-X/Psd, Removal Cross Section
Turkish CoHE Thesis Center URL
WoS Q
N/A
Scopus Q
Q4
Source
International Journal of Computational and Experimental Science and Engineering
Volume
9
Issue
4
Start Page
388
End Page