Implementation of a Non-Linear Adaptive Filter Based Sag Detection Method for Dynamic Voltage Restorers Under Unbalanced Fault Conditions

dc.contributor.author Cuma, M. Ugras
dc.contributor.author Teke, Ahmet
dc.contributor.author Meral, M. Emin
dc.contributor.author Bayindir, K. Cagatay
dc.contributor.author Tumay, Mehmet
dc.date.accessioned 2025-05-10T17:44:42Z
dc.date.available 2025-05-10T17:44:42Z
dc.date.issued 2013
dc.description Teke, Ahmet/0000-0003-2610-9576; Tumay, Mehmet/0000-0002-6055-3761; Meral, Mehmet Emin/0000-0003-0841-4630 en_US
dc.description.abstract The most common power quality problems in distribution systems are related to unbalanced voltage sags. Voltage sags must be detected quickly and corrected in a minimum amount of time. One of the most widely used methods for sag detection is based on the d-q transformation. This method has the disadvantage of missing the detection of unbalanced faults, because this method uses a voltage sag level signal obtained from the average of 3 phases for sag detection. In this paper, an adaptive filter sag detection method is proposed for Dynamic Voltage Restorers (DVR) under unbalanced fault conditions. The proposed DVR controller is able to detect balanced, unbalanced and single phase voltage sags. A novel reference voltage generation method is also presented. To validate the proposed control methods, a 3-phase DSP controlling a DVR prototype with a power rating of 1.5-kVA has been developed. Finally, experimental results are presented to verify the performance of the proposed control methods. en_US
dc.description.sponsorship Electrical, Electronics and Informatics Research Group of the Scientific and Technological Research Council of Turkey [EEEAG-106E188] en_US
dc.description.sponsorship The authors would like to acknowledge the Electrical, Electronics and Informatics Research Group of the Scientific and Technological Research Council of Turkey (Project No: EEEAG-106E188) for full financial support. en_US
dc.identifier.doi 10.6113/JPE.2013.13.2.304
dc.identifier.issn 1598-2092
dc.identifier.issn 2093-4718
dc.identifier.scopus 2-s2.0-84878156875
dc.identifier.uri https://doi.org/10.6113/JPE.2013.13.2.304
dc.identifier.uri https://hdl.handle.net/20.500.14720/16133
dc.language.iso en en_US
dc.publisher Springer Heidelberg en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Dynamic Voltage Restorer en_US
dc.subject Power Quality en_US
dc.subject Reference Voltage Generation en_US
dc.subject Sag Detection en_US
dc.title Implementation of a Non-Linear Adaptive Filter Based Sag Detection Method for Dynamic Voltage Restorers Under Unbalanced Fault Conditions en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.id Teke, Ahmet/0000-0003-2610-9576
gdc.author.id Tumay, Mehmet/0000-0002-6055-3761
gdc.author.id Meral, Mehmet Emin/0000-0003-0841-4630
gdc.author.scopusid 55746250400
gdc.author.scopusid 24774045100
gdc.author.scopusid 24921917000
gdc.author.scopusid 14018856700
gdc.author.scopusid 57033877100
gdc.author.wosid Teke, Ahmet/A-9464-2010
gdc.author.wosid Tumay, Mehmet/J-7480-2018
gdc.author.wosid Bayindir, Kamil/Aaa-2250-2020
gdc.author.wosid Cuma, Mehmet/J-6405-2012
gdc.coar.access open access
gdc.coar.type text::journal::journal article
gdc.description.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
gdc.description.departmenttemp [Cuma, M. Ugras; Teke, Ahmet; Bayindir, K. Cagatay; Tumay, Mehmet] Cukurova Univ, Dept Elect & Elect Engn, Adana, Turkey; [Meral, M. Emin] Yuzuncu Yil Univ, Dept Elect & Elect Engn, Van, Turkey en_US
gdc.description.endpage 312 en_US
gdc.description.issue 2 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality Q3
gdc.description.startpage 304 en_US
gdc.description.volume 13 en_US
gdc.description.woscitationindex Science Citation Index Expanded
gdc.description.wosquality Q4
gdc.identifier.wos WOS:000316160300015
gdc.index.type WoS
gdc.index.type Scopus

Files