Voltammetric Behavior of Rutin at a Boron-Doped Diamond Electrode. Its Electroanalytical Determination in a Pharmaceutical Formulation

dc.authorid Senturk, Zuhre/0000-0002-0356-9345
dc.authorid Yardim, Yavuz/0000-0002-9587-096X
dc.authorid Talay Pinar, Pinar/0000-0003-1027-1456
dc.authorscopusid 55807475500
dc.authorscopusid 55511747958
dc.authorscopusid 7004177719
dc.authorwosid Talay Pınar, Pınar/Jfj-2292-2023
dc.authorwosid Senturk, Zuhre/Aas-5179-2020
dc.contributor.author Pinar, Pinar Talay
dc.contributor.author Yardim, Yavuz
dc.contributor.author Senturk, Zuhre
dc.date.accessioned 2025-05-10T17:44:48Z
dc.date.available 2025-05-10T17:44:48Z
dc.date.issued 2013
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Pinar, Pinar Talay; Senturk, Zuhre] Yuzuncu Yil Univ, Dept Analyt Chem, Fac Sci, TR-65080 Van, Turkey; [Yardim, Yavuz] Yuzuncu Yil Univ, Dept Analyt Chem, Fac Pharm, TR-65080 Van, Turkey en_US
dc.description Senturk, Zuhre/0000-0002-0356-9345; Yardim, Yavuz/0000-0002-9587-096X; Talay Pinar, Pinar/0000-0003-1027-1456 en_US
dc.description.abstract This paper examined for the first time, the possibilities of the usage of a boron-doped diamond electrode for the redox behavior of rutin using cyclic and adsorptive stripping voltammetry. The cyclic voltammograms showed a pair of redox peaks at lower potentials followed by an irreversible oxidation peak at higher positive potential. Using square-wave adsorptive stripping voltammetry, the compound yielded a well-defined voltammetric response in Britton-Robinson buffer, pH 4.0 at +0.48 V (vs. Ag/AgCl) (after 60 s accumulations at a fixed potential of 0.2 V). The calibration curve was linear in the concentration range from 0.01 A mu g mL(-1) to 0.1 A mu g mL(-1) (1.64x10(-8) M - 1.64x10(-7) M). A detection limit of 0.0017 A mu g mL(-1) (2.78x10(-9) M) was observed without any chemical modifications and electrochemical surface pretreatments. As an example, the practical applicability of boron-doped diamond electrode was tested with the measurement of rutin in dietary supplement products. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.2478/s11532-013-0292-6
dc.identifier.endpage 1681 en_US
dc.identifier.issn 1895-1066
dc.identifier.issn 1644-3624
dc.identifier.issue 10 en_US
dc.identifier.scopus 2-s2.0-84880885233
dc.identifier.scopusquality N/A
dc.identifier.startpage 1674 en_US
dc.identifier.uri https://doi.org/10.2478/s11532-013-0292-6
dc.identifier.uri https://hdl.handle.net/20.500.14720/16170
dc.identifier.volume 11 en_US
dc.identifier.wos WOS:000322010400011
dc.identifier.wosquality N/A
dc.language.iso en en_US
dc.publisher Sciendo en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Rutin en_US
dc.subject Boron-Doped Diamond Electrode en_US
dc.subject Square-Wave Adsorptive Stripping Voltammetry en_US
dc.subject Dietary Supplement. en_US
dc.title Voltammetric Behavior of Rutin at a Boron-Doped Diamond Electrode. Its Electroanalytical Determination in a Pharmaceutical Formulation en_US
dc.type Article en_US
dspace.entity.type Publication

Files