Hemodynamic Monitoring Using a Pulse Counter Vigileo Flotrac Cardiac Output System in Transapical Off-Pump Minimally Invasive Mitral Valve Repair

No Thumbnail Available

Date

2020

Journal Title

Journal ISSN

Volume Title

Publisher

Yuzuncu Yil Universitesi Tip Fakultesi

Abstract

The aim of this study was to present our anesthetic management and early hemodynamic recovery after transapical off-pump neochords implantation. Observational prospective study. The perioperative records of 13 patients who underwent mitral valve repair using the Neochord DS1000 system were analyzed. Hemodynamic measurements recorded with the Vigileo Flotrac invasive arterial cardiac output system were evaluated. Thirteen patients were included in the study. Transfusions of a total of 2 U of erythrocytes and 11 U of plasma were performed. After Neochord implantation, the mean cardiac output increased at a statistically significant level according to the values measured after induction p = 0.003. Increased cardiac output measurement after placement of the neochordaes and elimination of insufficiency have emerged as indications of early hemodynamic recovery. © 2020, Yuzuncu Yil Universitesi Tip Fakultesi. All rights reserved.

Description

Keywords

Cardiac Output, Chorda Tendinea, Mitral Valve Prolapse

Turkish CoHE Thesis Center URL

WoS Q

N/A

Scopus Q

Q4

Source

Eastern Journal of Medicine

Volume

25

Issue

2

Start Page

177

End Page

183
Google Scholar Logo
Google Scholar™