Electrochemical Determination of Norepinephrine by Adsorptive Stripping Voltammetry Using a Bare Boron-Doped Diamond Electrode

dc.authorid Yardim, Yavuz/0000-0002-9587-096X
dc.authorid Levent, Abdulkadir/0000-0001-5792-419X
dc.authorid Senturk, Zuhre/0000-0002-0356-9345
dc.authorscopusid 35740840400
dc.authorscopusid 55511747958
dc.authorscopusid 6602133530
dc.authorscopusid 7004177719
dc.contributor.author Keskin, E.
dc.contributor.author Yardim, Y.
dc.contributor.author Levent, A.
dc.contributor.author Şentürk, Z.
dc.date.accessioned 2025-05-10T17:34:59Z
dc.date.available 2025-05-10T17:34:59Z
dc.date.issued 2019
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Keskin] Ertuǧrul, Department of Analytical Chemistry, Adiyaman Üniversitesi, Adiyaman, Turkey; [Yardim] Yavuz, Department of Analytical Chemistry, Van Yüzüncü Yıl Üniversitesi, Van, Turkey; [Levent] Abdulkadir, Department of Analytical Chemistry, Batman University, Batman, Turkey; [Şentürk] Zühre, Department of Analytical Chemistry, Van Yüzüncü Yıl Üniversitesi, Van, Turkey en_US
dc.description.abstract A boron-doped diamond electrode was used for the first time for sensitive and selective analysis of norepinephrine (NE) using square wave voltammetry (SWV) technique. NE displayed one well-defined, irreversible and adsorption-controlled oxidation peak at about +0.85 V (vs. Ag/AgCl) in Britton-Robinson buffer (BR, 0.1 M, pH 2.0) using cyclic voltammetry (CV) technique. The effect of supporting electrolyte, solution pH and instrumental variables on oxidation peak current were optimized. In optimal experiment conditions, it was found that there was an excellent correlation between oxidation peak current and NE concentration in the range of 1 to 100 μg mL-1 (4.9×10-6 M-4.9×10-4 M) with a detection limit of 0.254 μg mL-1 (1.2×10-6 M) in 0.1 M BR buffer (pH 2.0) solution employing square-wave stripping mode. The developed technique can be used for the quantification of NE in the pharmaceutical formulation with acceptable recoveries. © 2020 Elsevier B.V., All rights reserved. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.33224/rrch.2019.64.12.06
dc.identifier.endpage 1072 en_US
dc.identifier.issn 0035-3930
dc.identifier.issue 12 en_US
dc.identifier.scopus 2-s2.0-85086426814
dc.identifier.scopusquality Q4
dc.identifier.startpage 1063 en_US
dc.identifier.uri https://doi.org/10.33224/rrch.2019.64.12.06
dc.identifier.volume 64 en_US
dc.identifier.wos WOS:000520019800006
dc.identifier.wosquality Q4
dc.language.iso en en_US
dc.publisher Editura Academiei Romane en_US
dc.relation.ispartof Revue Roumaine De Chimie en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.title Electrochemical Determination of Norepinephrine by Adsorptive Stripping Voltammetry Using a Bare Boron-Doped Diamond Electrode en_US
dc.type Article en_US
dspace.entity.type Publication

Files