YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Graphene/Nafion Composite Film Modified Glassy Carbon Electrode for Simultaneous Determination of Paracetamol, Aspirin and Caffeine in Pharmaceutical Formulations

dc.authorid Senturk, Zuhre/0000-0002-0356-9345
dc.authorid Levent, Abdulkadir/0000-0001-5792-419X
dc.authorid Yardim, Yavuz/0000-0002-9587-096X
dc.authorid Celebi, Metin/0000-0003-1475-8878
dc.authorscopusid 57188666717
dc.authorscopusid 55511747958
dc.authorscopusid 25951378700
dc.authorscopusid 6602133530
dc.authorscopusid 7004177719
dc.authorwosid Senturk, Zuhre/Aas-5179-2020
dc.authorwosid Levent, Abdulkadir/V-5418-2017
dc.authorwosid Celebi, Metin/Gwd-1423-2022
dc.contributor.author Yigit, Aydin
dc.contributor.author Yardim, Yavuz
dc.contributor.author Celebi, Metin
dc.contributor.author Levent, Abdulkadir
dc.contributor.author Senturk, Zuhre
dc.date.accessioned 2025-05-10T17:41:00Z
dc.date.available 2025-05-10T17:41:00Z
dc.date.issued 2016
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Yigit, Aydin; Yardim, Yavuz] Yuzuncu Yil Univ, Dept Analyt Chem, Fac Pharm, TR-65080 Van, Turkey; [Celebi, Metin] Yuzuncu Yil Univ, Dept Inorgan Chem, Fac Sci, TR-65080 Van, Turkey; [Levent, Abdulkadir] Batman Univ, Hlth Serv Vocat Coll, TR-72100 Batman, Turkey; [Senturk, Zuhre] Yuzuncu Yil Univ, Dept Analyt Chem, Fac Sci, TR-65080 Van, Turkey en_US
dc.description Senturk, Zuhre/0000-0002-0356-9345; Levent, Abdulkadir/0000-0001-5792-419X; Yardim, Yavuz/0000-0002-9587-096X; Celebi, Metin/0000-0003-1475-8878 en_US
dc.description.abstract A graphene-Nafion composite film was fabricated on the glassy carbon electrode (GR-NF/GCE), and used for simultaneous determination of paracetamol (PAR), aspirin (ASA) and caffeine (CAF). The electrochemical behaviors of PAR, ASA and CAF were investigated by cyclic voltammetry and square-wave adsorptive anodic stripping voltammetry. By using stripping one for simultaneous determination of PAR, ASA and CAF, their electrochemical oxidation peaks appeared at +0.64,1.04 and 1.44 V, and good linear current responses were obtained with the detection limits of 18 ng mL(-1) (1.2 x 10(-9) M), 11.7 ng mL(-1) (6.5 x 10(-8) M) and 7.3 ng mL(-1) (3.8 x 10(-8) M), respectively. Finally, the proposed electrochemical sensor was successfully applied for quantifying PAR, ASA and CAF in commercial tablet formulations. (C) 2016 Elsevier B.V. All rights reserved. en_US
dc.description.sponsorship Scientific and Technological Research Council of Turkey (TUBITAK) [KBAG114Z405] en_US
dc.description.sponsorship The authors gratefully acknowledge financial support from The Scientific and Technological Research Council of Turkey (TUBITAK) (Project number: KBAG114Z405). en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1016/j.talanta.2016.05.046
dc.identifier.endpage 29 en_US
dc.identifier.issn 0039-9140
dc.identifier.issn 1873-3573
dc.identifier.pmid 27343573
dc.identifier.scopus 2-s2.0-84970027928
dc.identifier.scopusquality Q1
dc.identifier.startpage 21 en_US
dc.identifier.uri https://doi.org/10.1016/j.talanta.2016.05.046
dc.identifier.uri https://hdl.handle.net/20.500.14720/15380
dc.identifier.volume 158 en_US
dc.identifier.wos WOS:000379370400004
dc.identifier.wosquality Q1
dc.language.iso en en_US
dc.publisher Elsevier Science Bv en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Paracetamol en_US
dc.subject Aspirin en_US
dc.subject Caffeine en_US
dc.subject Graphene-Nafion Composite Film Modified Glassy Carbon Electrode en_US
dc.subject Pharmaceutical Formulation en_US
dc.title Graphene/Nafion Composite Film Modified Glassy Carbon Electrode for Simultaneous Determination of Paracetamol, Aspirin and Caffeine in Pharmaceutical Formulations en_US
dc.type Article en_US

Files