YYÜ GCRIS Basic veritabanının içerik oluşturulması ve kurulumu Research Ecosystems (https://www.researchecosystems.com) tarafından devam etmektedir. Bu süreçte gördüğünüz verilerde eksikler olabilir.
 

Usability of Transthoracic Shear Wave Elastography in Differentiation of Subpleural Solid Masses

dc.authorid Aydin, Yener/0000-0001-6523-2572
dc.authorid Batur, Abdussamet/0000-0003-2865-9379
dc.authorid Dundar, Ilyas/0000-0002-1429-077X
dc.authorid Uney, Ibrahim Halil/0000-0002-8801-7661
dc.authorid Yildiz, Hanifi/0000-0003-0735-5034
dc.authorscopusid 54998741200
dc.authorscopusid 55682194900
dc.authorscopusid 57190380888
dc.authorscopusid 56690325400
dc.authorscopusid 57204901667
dc.authorscopusid 23003810700
dc.authorscopusid 21333559300
dc.authorwosid Batur, Abdussamet/Aac-1482-2020
dc.authorwosid Aydin, Yener/Abe-9825-2021
dc.authorwosid Yavuz, Alpaslan/H-3947-2014
dc.authorwosid Durmaz, Fatma/Abc-4072-2021
dc.authorwosid Dundar, Ilyas/Aba-7303-2020
dc.authorwosid Yildiz, Hanifi/A-3908-2019
dc.contributor.author Ozgokce, Mesut
dc.contributor.author Yavuz, Alpaslan
dc.contributor.author Akbudak, Ibrahim
dc.contributor.author Durmaz, Fatma
dc.contributor.author Uney, Ibrahim
dc.contributor.author Aydin, Yener
dc.contributor.author Dundar, Ilyas
dc.date.accessioned 2025-05-10T17:43:53Z
dc.date.available 2025-05-10T17:43:53Z
dc.date.issued 2018
dc.department T.C. Van Yüzüncü Yıl Üniversitesi en_US
dc.department-temp [Ozgokce, Mesut; Yavuz, Alpaslan; Durmaz, Fatma; Batur, Abdussamet; Arslan, Harun; Dundar, Ilyas] Yuzuncu Yil Univ, Med Fac, Dept Radiol, TR-65100 Van, Turkey; [Akbudak, Ibrahim] Batman Publ Hosp, Radiol Clin, Batman, Turkey; [Uney, Ibrahim; Yildiz, Hanifi] Yuzuncu Yil Univ, Med Fac, Dept Chest Dis, Van, Turkey; [Aydin, Yener] Ataturk Univ, Med Fac, Dept Chest Surg, Erzurum, Turkey en_US
dc.description Aydin, Yener/0000-0001-6523-2572; Batur, Abdussamet/0000-0003-2865-9379; Dundar, Ilyas/0000-0002-1429-077X; Uney, Ibrahim Halil/0000-0002-8801-7661; Yildiz, Hanifi/0000-0003-0735-5034 en_US
dc.description.abstract In this study, the effectiveness of transthoracic ultrasound elastography in the benign and malign distinction of subpleural/pleural solid lesions was investigated.Between July 2015 and December 2016, 33 consecutive patients with subpleural solid lesions detected via computed tomography (CT) of the thorax were identified and prospectively included in this study. The average for each lesion's shear wave velocity (SWV) value was detected, and benign and malignant lesions' SWV values are statistically compared. The CT and pathology results were used as a reference to compare these values. A receiver operating characteristic analysis was used to determine the cutoff value for benign/malignant neoplasms.The 33 patients (10 female, 23 male) included in the study had a mean age of 56.2 +/- 15.40 years (range, 17-84 years), and the mean SWV value of the lesions in 13 (39%) cases evaluated benign after a CT scan, histopathological examination, or both 2.18 +/- 0.49 m/s. The mean SWV value of the lesions which were histopathologically diagnosed as malign in 23 (61%) cases was 3.50 +/- 0.69 m/s. (P < 0.001). When the cutoff value was set as 2.47 m/s for the SVW value, sensitivity and specificity were determined to be 97.7%.The present study has shown that transthoracic ultrasound shear wave elastography can be an effective radiological examination method in the benign and malign differentiation of subpleural lesions and has the potential for use in the routine clinical application of transthoracic ultrasound elastography, a noninvasive method for evaluating the malignancy potentials of such lesions. en_US
dc.description.woscitationindex Science Citation Index Expanded
dc.identifier.doi 10.1097/RUQ.0000000000000374
dc.identifier.endpage 237 en_US
dc.identifier.issn 0894-8771
dc.identifier.issn 1536-0253
dc.identifier.issue 4 en_US
dc.identifier.pmid 30169488
dc.identifier.scopus 2-s2.0-85057766455
dc.identifier.scopusquality Q3
dc.identifier.startpage 233 en_US
dc.identifier.uri https://doi.org/10.1097/RUQ.0000000000000374
dc.identifier.uri https://hdl.handle.net/20.500.14720/16010
dc.identifier.volume 34 en_US
dc.identifier.wos WOS:000452680700007
dc.identifier.wosquality Q4
dc.language.iso en en_US
dc.publisher Lippincott Williams & Wilkins en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Ultrasound en_US
dc.subject Shear Wave Elastography en_US
dc.subject Subpleural Lesion en_US
dc.subject Lung Cancer en_US
dc.title Usability of Transthoracic Shear Wave Elastography in Differentiation of Subpleural Solid Masses en_US
dc.type Article en_US

Files